Continued…
Dynamic DL Controller
VSI ‘Lock’ Function*
Your VSI controller is equipped with a lock function to prevent any
unauthorised use. To lock the controller:
•
When the power is on, press and hold the power button for
about 1 second until the system bleeps.
•
Move the joystick forward until it bleeps, then move it to the
back position until you hear a bleep.
•
Release the joystick – you should now hear a long bleep, this
indicates the system is now locked.
To unlock the controller:
•
Press the power button until the speed indicator lights go from
left to right.
•
Move the joystick forward until it bleeps, then move it to the
back position until you hear a bleep.
Release the joystick – you should hear another bleep, this indicates
that the system is unlocked and ready for use.
*VSI controllers can be re-programmed using a PP1 unit which can
enable/disable this function.
Flash
Code
Fault Type
Suggested Actions
1 Low
Battery
Voltage
Fault
Check battery voltage is above 17v.
Check battery connections and terminals.
Check condition of batteries.
2
High Voltage Fault
Check battery voltage is below 32v.
Check battery wiring and terminating is
secure.
3
Left Motor Fault
Check left motor, connections and cables.
4
Right Motor Fault
Check right motor, connections and cables.
5
Park Brake Fault
Check the brakes, connection and cables
6
Controller Fault
Contact Service Agent.
Note:
In some cases a motor fault that occurs
when driving may cause a 6 flash fault to be
registered.
7 Motor Stalled or
Joystick Out of neutral
at power up.
Ensure joystick is released at power up.
Ensure motors are free to turn and power off
and on.