![RollSeal SC-325M Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/rollseal/sc-325m/sc-325m_installation-manual_1483772019.webp)
Part No 4801-5162 Rev 09-2019
RS-500/600 M Series Doors
Page 19
9
Installation of RS-500/600 Series Doors
9.1
RS-500/600 Variations
As detailed in the dimension section above, there are various configurations of doors that are encompassed by the RS-
500/600 model. The “Standard” RS-500/600 is the basic door that is for use in cooler and non-low temp applications.
The “CMS Kit” configuration is an addition to this “Standard” door, although it requires that the door is ordered with
this kit to allow for manufacturing modifications. As shown in the dimensions listed above, it is acceptable to have a
standard door with a CMS Kit up to 12’ wide and 12’ tall. If the door is being used for low temperature applications
such as a Freezer, the system must be ordered with this intent and is limited to 7’ wide and 10’ tall.
9.2
Tools Required
3/8 in. (10 mm) Power screwdriver (portable)
3/16 in. (5 mm) Drill bit and power drill
Socket
Hammer
Tape measure
Carpenter's level
NOTE: Other Tools May Be Required According To Installation.
9.3
Overview
The RS-500/600 Series doors are shipped with pre-assembled vertical members (left track and right track), and a pre-
assembled horizontal member (head unit). When components are received, check for damaged, loose or missing parts.
If there are damaged or missing parts contact your RollSeal distributor immediately. Please read and understand all
instructions in this manual before beginning installation.
9.4
Adjusting the Door Framing or Clear Opening
Locate your particular system in the appropriate
Tables 1-4
. Read the value of height and width of the clear opening
for the door size that you are installing. This gives the required dimensions of the clear opening. If necessary, adjust
the dimensions of the mounting posts or framing members to the height and width of your RS-500/600 series door
system as shown. Refer to
Section 9.5, Page 20, Diagram 9A
for details of attaching door to framing members.
Framing material must provide suitable support for attachment of screws. Make sure that mounting posts or framing
members are positioned so that the screw holes of the outer flanges of the vertical members will align with the mounting
posts or framing members.
NOTE: Make sure that there is space for appropriate motor, control box or Condensation Management
System (CMS) without encountering any obstructions during installation. Refer to appropriate cut
sheet, and view the appropriate drawing of the door and operator to ensure required footprint.
NOTE: Allow 1' (30.4 cm) minimum, preferably 18" (45.7 cm) clearance above the Head Unit for future panel
maintenance or replacement.