background image

REAR PANEL DESCRIPTION
Note: Channel One descriptions are identical to Channel Two

Outputs: XLR balanced and 1/4" unbalanced connectors for connecting
the RP583 to a mixer or other line level input.

Side Chain Input: 1/4" unbalanced jack for receiving incoming signals to
directly access the detector circuit of the compressor.

Side Chain Output: 1/4" unbalanced jack for sending out the signal
from the RP583.  This jack may also be used as a pre-Output Level
output.
Note: The Side Chain Inputs and Outputs are not effects loops, they
break the signal path of the RP583 control circuits.

Inputs: XLR balanced and 1/4" unbalanced connectors for connecting
line level signals to the RP583.

SPECIFICATIONS
Frequency Response

20 Hz - 40 kHz

Input Impedance

10K

 balanced

1M

 unbalanced

THD + Noise

<0.1% typical

S/N Ratio

90 dB

Indicators

2: Active LEDs
2: Analog Meters

Input/Output jacks

XLR balanced
1/4" unbalanced

Side Chain:

1/4" unbalanced

Dimensions

3.5" x 6" x 19"
(89mm X 162mm X 482mm)

Weight

6 lbs. (2.72 Kg)

Power

120VAC (230VAC) 15VA

FRONT PANEL DESCRIPTION
Note: Channel One descriptions are identical to Channel Two

Active Switch: Engages and disengages the compression.

Output Level: Varies the overall signal level from the RP583.

Threshold: Sets the level at which the income signal must overcome in
order for the RP583 to begin compressing.

Ratio: The signal to compression ratio - sets the amount of increase in
input signal required to raise the output signal 1 dB.

Attack: Varies the amount of time taken for the RP583 to begin com-
pressing once the Threshold level has been reached.

Release: Varies the amount of time taken for the  RP583 to return to
normal gain once the signal has dropped below the Threshold level.

Stereo Link Switch: Links the detector circuits of both channels to-
gether. 

NOTE: CHANNEL TWO BECOMES THE MASTER CHANNEL.

Meter Switch: Switches the signal metering from indicating the output
jack level, to indicating the amount of gain reduction.

VU Meter: Indicates either the output signal level, or the amount of gain
reduction, depending on the position of the Meter Switch.
NOTE: THE INPUT SIGNAL LEVEL MAY ALSO BE METERED BY
PRESSING OUT THE ACTIVE SWITCH, THUS BYPASSING THE
COMPRESSOR CIRCUITS.

Power Switch: Turns the RP583 main power on and off.

2

3

20

10

5

3

0

3

6

dB

+4 REF

OUTPUT

GAIN
REDUCTION

ACTIVE

OUTPUT LEVEL

THRESHOLD

RATIO

ATTACK

RELEASE

METER

ACTIVE

-  OO     dB     +22

-20      dB    +20

.5      ms    100

.1       Sec     2

METER

CHANNEL ONE

CHANNEL TWO

2:1            OO :1 

4:1                        5:1

4:1                        5:1

STEREO

LINK

20

10

5

3

0

3

6

dB

Studio Dual Tube Compressor/Limiter

RP583

CHANNEL

ONE

CHANNEL

TWO

0

0

-  OO     dB     +22

-20      dB    +20

.5      ms    100

.1       Sec      2

2:1            OO :1 

CAUTION

WARNING: 

DO NOT EXPOSE THIS  EQUIPMENT TO RAIN 

OR MOISTURE.

CAUTION: 

TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT

NOT REMOVE BACK. NO USER SERVICABLE PARTS INSIDE. REFER 
SERVICING TO QUALIFIED SERVICE PERSONNEL.
                            RISQUE DE CHOC - NE PAS ENLEVER

RISK OF ELECTRIC SHOCK

DO NOT OPEN

120 VAC

50/60 Hz 15 VA

MADE IN U.S.A.

MODEL RP583

SERIAL NUMBER

583-

OUTPUT

C H A N N E L   T W O

SIDE CHAIN

INPUT

OUTPUT

C H A N N E L   O N E

SIDE CHAIN

INPUT

BAL

UNBAL

INPUT

OUTPUT

UNBAL

BAL

BAL

UNBAL

INPUT

OUTPUT

UNBAL

BAL

Отзывы: