background image

6

Rollerdor RD20X2ANSA Control Box,  Edition 2022/1

Handsets that come supplied with the receiver 
box are normally programmed in and work in a 
sequential operation but if any extra handsets need 
programming please follow instructions below.

Press and hold the operation button on 
receiver box next to the RED LED for roughly 
5 seconds and release when the RED LED 
goes out 

(fig.13 & fig.14)

The RED LED will flash once to say it 
is programming mode:  With the new 
unprogrammed handset in hand, press and 
release the top button 

(fig.15) 

and the red 

LED will flash once again, repeat for every 
handset to be added.

After programming all desired handsets 
wait 30 seconds for the RED LED to come 
back on solid and the door is out of 
programming mode and ready to use, test 
handset to check and repeat the process if 
programming hasn’t worked.

SEQUENTIAL OPERATION

Turn mains power off.

Move dip switch number 6 in the up position 

(fig.16)

.

Turn mains power on, the YELLOW LED “set 
radio” will light up for 5 seconds.

Turn mains power off, Move dip switch number 
6 back down, turn mains power on. All handsets 
are wiped.

CLEARING MEMORY OF REMOTE 

CONTROL HANDSETS

fig.16

3. PROGRAMMING OF REMOTE 

CONTROL HANDSETS

fig.14

fig.15

Pictures are for illustration purposes only, connector blocks are not provided and further fittings may be required. 

Содержание RD20X2ANSA

Страница 1: ...Rollerdor RD20X2ANSA Control Box Edition 2022 1 Installation Guide for Roller Garage Doors RD20X2ANSA Control Box Edition 2022 1...

Страница 2: ...cable out of the way of the working mechanism 5 Motor Wiring Connection of the motor s open and close cables black brown must suit the motor handing as per the diagram fig 4 6 Safety Brake if you hav...

Страница 3: ...3 Rollerdor RD20X2ANSA Control Box Edition 2022 1 fig 5 fig 7 fig 6 fig 8 Pictures are for illustration purposes only connector blocks are not provided and further fittings may be required...

Страница 4: ...both sides attach the magnet making sure it is the correct way up fig 9 3 Close the curtain all the way to the floor wipe both of the guide runners to make sure they are clear of all debris and dust...

Страница 5: ...xt to RED LED fig 13 for 1 second then release C Wait 2 seconds then press and release the operation button The door will start to close and will stop just before it touches the floor The curtain will...

Страница 6: ...ndset to be added 3 After programming all desired handsets wait 30 seconds for the RED LED to come back on solid and the door is out of programming mode and ready to use test handset to check and repe...

Страница 7: ...r it will automatically reset after 15 minutes ALARM SYSTEM MR 1 Open the door fully remove the connection going into STOP terminal on the main board fig 5 fig 6 the LED next to Status should turn fro...

Страница 8: ...OWN Wire COM Common wire from supply to switch Rocker Switch fig 18 4 Up wire 3 Down wire from rocker switch 5 Common wire for the supply to the switch Fit Link wire from 5 to 2 To open rocker switch...

Страница 9: ...and secure in place with the two fixing screws fig 20 PAIRING USING ACCESS CODE 1 The keypad is supplied with factory pre set master code number 9999 and factory access code number 1234 2 To pair key...

Страница 10: ...sh rapidly if the battery is low indicating the battery needs replacing 5 The Keypad has an anti tamper feature if 6 9 incorrect random access codes are entered or 36 incorrect keystrokes the unit wil...

Страница 11: ...11 Rollerdor RD20X2ANSA Control Box Edition 2022 1 5 OPERATING DIAGNOSTICS Pictures are for illustration purposes only connector blocks are not provided and further fittings may be required...

Страница 12: ...owthorpe Employment Area Norwich Norfolk NR5 9JD 44 0 1603 743215 sales rollerdor net www rollerdor net Company Registration Number 10676267 Registered Office Address Rollerdor Ltd Bankside 300 Peachm...