4. WAY OF FUNCTIONING

 

 

This modular high power gas fryer has a capacity of 10L for 2,5 Kgs fresh or frozen 
French fries, doughnuts, fish etc. 

 

 

The drawn and lightly tilted tank in only one piece is especially made for the direct flow 
of the oil without rest of oil in the tank. The draining is safe thanks to the tap placed on 
the front of the fryer. 

 

It is possible to adapt this fryer on a cabinet with 100mm feet

 

 

To  turn  on  the  fryer,  just  press  and  turn  the  thermostatic  tap  (n°3  on  picture)  anti

-

clockwise opposite the star position.

 

Keep pressed and turn on the pilot light thanks to the piezo (n°1 on picture) 

 

Press for about 15 seconds and turn the knob (n°3 on picture) on position 8 to turn on 
the burner

 

Turn the power control knob (n°3 on picture) to the desired position.

 

 

 

 

5. FUNCTIONING / HANDLING

 

  

a) Installation/Assembly:

 

 

-

 Unpack carefully the device of its packaging.

 

-

 Remove the protective film around the machine

 

-

 Screw up the feet and  the handle on the lid. 

 

-

 Place the fryer on a plane and heatproof surface.

 

-

 Never place the device near a wall or near a partition makes of combustible materials 

even if it is very well isolated.

 

-

 A distance of minimum 10 cm with the partition or the wall is necessary.

 

-

 Place all the accessories

 

-

 Keep the lid near the fryer to enable you covering it after use or in case of fire.

 

 

 

b) First starting

:

 

 

Before the first use, wash the machine and all accessories with hot soapy water and 
dry them with a soft cloth (see 6. Cleaning and maintenance)

 

 

Gas connection

 

 

The  appliances  run  on  the  following  gases:  Butane  G30,  Propane  G31,  Natural  gas 
G20/G25. The appliances are originally delivered  with a Butane/Propane injector cor-
responding to the category II2E+3+. The connection is made thanks to a thread 1/2. 

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

100°C

 

113°C

 

126°C

 

139°C

 

152°C

 

165°C

 

178°C

 

190°C

 

5

 

Содержание RFG 12

Страница 1: ...INSTRUCTION MANUAL FOR USE AND INSTALLATION GAS FRYER RFG 12 Made in France Made in France Made in France Made in France December 2014 ...

Страница 2: ...uctions 3 2 Contents of cardboard packaging 4 3 Conformity of use 4 4 Way of functioning 5 5 Functioning Manipulation 5 6 7 6 Cleaning and maintenance 8 7 Technical specifications 9 Appendix part list and exploded view 10 11 2 ...

Страница 3: ...o not use the appliance for other functions than determined use Do not leave the pipe or hose purchased separately from a specialised shop in the contact of hot surfaces The appliance should not be used close to combustible materials During use look after not to obstruct hearings of aeration of the appliance Never exceed the maximum capacity of your fryer which is of 2 5kg Never place the lid on t...

Страница 4: ... basket A basket hoder A set of natural gas injectors The present note See the exploded of the RFG 12 at the end of the document 3 CONFORMITY OF USE Use the machine only to cook some food 4 Piezo power on knob Thermostatic tap power regulation Draining tap 1 2 3 1 2 3 ...

Страница 5: ...G a Installation Assembly Unpack carefully the device of its packaging Remove the protective film around the machine Screw up the feet and the handle on the lid Place the fryer on a plane and heatproof surface Never place the device near a wall or near a partition makes of combustible materials even if it is very well isolated A distance of minimum 10 cm with the partition or the wall is necessary...

Страница 6: ...ation Check the supply pressure using a manometer when all the burners are lit It must be equal to the indications on the rating plate The fresh air flow required for combustion air supply is RFG 12 13m3 h General conditions of installation The installation and maintenance of the appliance must be carried out in compliance with the statutory texts and good practices in force mainly General specifi...

Страница 7: ...liance simultaneously with the set knob Set knob n 3 on picture Switches on the appliance knob pressed simultaneously with piezo Controls power 7 Country of destination Category Gas Pressures Diameter of in jector FR BE II2E 3 G20 G25 G30 G31 20 25 28 30 37 140 90 LU DE II2E3B P G20 G30 G31 20 50 140 80 LU II2E3 G20 G30 G31 20 28 30 37 140 80 AT CH CY DK EE FI HR LT LV NO RO SE SI SK TR II2H3B P G...

Страница 8: ...he appliance is completely switched off Close the butane or propane cartridge Clean the appliance See 6 Cleaning d Breakdown repair In case of breakdown or of damaged part please call your after sales service and confide any technical operation to qualified person When you contact the after sales service of your distributor or your store give him the complete reference of your device commercial na...

Страница 9: ... respect cur rent regulations or instructions appearing in this user guide Cannot benefit from the guarantee the repairs required as a result of false opera tions of inappropriate use of carelessness or of excess loads of the device as well as those resulting from defective installations The damage due to shocks bad weather is not flatware by the guarantee The ma terial travels at the risks of the...

Страница 10: ...10 Nomenclature Friteuse RFG 12 Spare parts FryerRFG 12 ...

Страница 11: ...11 ...

Страница 12: ...12 ...

Отзывы: