Hold 

P1 

button on motor head.

Press and release 

P1

 button on 

the motor head

SLEEP MODE

Enter Sleep Mode

Sleep mode is utilized to 

prevent a motor from incorrect 

configuration during other 

motor setup.

If multiple motors are grouped on a single channel, Sleep Mode may be used to put all but 1 motor to sleep, 

allowing programming of just the one motor that remains “Awake”.

Exit Sleep Mode: Method 1

Exit sleep mode once the shade 

is ready.

Exit Sleep Mode: Method 2

Remove power and then         

re-power the motor.

Motor Response

SLEEP MODE

10  WIND SENSOR FUNCTION

Approx.

Once the motor receives a command from the wind sensor the motor will respond accordingly. At this point 

the motor will ignore any other remote or sensor commands for 8 minutes. This function is needed to avoid 

contradicting multiple triggers. Keep this in mind when testing the motor with the remote after the wind 

sensor has been triggered. The wind sensor function is ON by default.

Note: Motor will jog to alert user if operated within the 8 minutes.

10.1  Wind Sensor Prioritize Function

Содержание AUTOMATE AX30

Страница 1: ...RONIC LIMIT FAVORITE POSITION IMPACT DETECTION AUTOMATE AX30 AX50 External Shade Motor combine the simple intuitive features of ARC Automate Radio Communication with the higher lifting capacity of an...

Страница 2: ...ust lower limit 11 4 5 Delete Upper Lower Limits 12 5 CASSETTE MODE 13 5 1 Initial Setup 13 5 1 1 Pair motor with controller 13 5 1 2 Check motor direction 13 5 2 Select Motor Mode 14 5 3 Set Limits 1...

Страница 3: ...ctive Deactivate Impact Detection Mode 23 7 ADD CONTROLLER AND CHANNEL 24 7 1 Using P2 Button on existing controller to add a new controller or channel 24 7 2 Using a pre existing controller to add or...

Страница 4: ...and clear from metal objects Do not cut the antenna Follow Rollease Acmeda installation instructions Before installation remove any unnecessary cords and disable any equipment not needed for powered o...

Страница 5: ...and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Страница 6: ...roller tube is clean and free from burrs Step 3 Fit required crown drive and bracket adapters Step 4 Slide Motor into tube Insert by aligning key way in crown and drive wheel into the tube Step 5 Moun...

Страница 7: ...coupled Isolate power prior to connecting or disconnecting this motor This connector must not be acces sible to the end user It shall be placed within a pelmet box or within a housing in accordance t...

Страница 8: ...P1 Press Condition Function Achieved Visual Feedback Audible Feedback Function Described Short Press If limit is NOT set None No Action None No Action If limits are set Operational control of motor r...

Страница 9: ...prior to setting limits Attention should be given Reversing motor direction using this method is only possible during initial set up Hold P1 button on motor head To check travel direction of shade pr...

Страница 10: ...or to setting limits to settle fabric After setting limits motor will automatically exit from initial set up mode Move shade to the desired highest or lowest position by pressing the UP or DOWN button...

Страница 11: ...n controller Hold DOWN and STOP on controller Move shade to the desired lowest position by pressing the DOWN button Move shade to the desired highest position by pressing the UP button To save upper l...

Страница 12: ...gramming Instructions AX30 AX50 External Shade Motor ROLLEASE ACMEDA 4 5 Delete Upper Lower Limits Press P2 on controller Press DOWN on controller Press P2 on controller Motor Response Motor Response...

Страница 13: ...prior to setting limits Attention should be given Reversing motor direction using this method is only possible during initial set up Hold P1 button on motor head To check travel direction of shade pr...

Страница 14: ...ODE Move shade to the highest position by pressing the UP button on controller Upper limit will be automatically set when motor stops Note On condition that lower limit has been set prior Move shade t...

Страница 15: ...ontroller Press P2 on controller Motor Response Motor Response Motor Response Move shade to Upper Lower Limits 5 4 1 Activate Deactivate Upper Limit Fabric Tension Press P2 on controller Press STOP on...

Страница 16: ...tor ROLLEASE ACMEDA 5 4 2 Activate Deactivate Lower limit Fabric Tension Press P2 on controller Press STOP on controller Press DOWN on controller ACTIVATE Motor Response Motor Response Motor Response...

Страница 17: ...prior to setting limits Attention should be given Reversing motor direction using this method is only possible during initial set up Hold P1 button on motor head To check travel direction of shade pr...

Страница 18: ...mode Move shade to the desired highest or lowest position by pressing the UP or DOWN buttons on controller To save upper limit hold UP and STOP To save lower limit hold DOWN and STOP Motor Response IM...

Страница 19: ...to the desired highest position by pressing the UP button To save upper limit hold UP and STOP Approx Approx Motor Response Motor Response 6 3 2 Adjust lower limit Hold DOWN and STOP on controller Mo...

Страница 20: ...on controller Press DOWN on controller Press P2 on controller Motor Response Motor Response Motor Response Move shade to Upper Lower Limits 6 4 FT Mode Overview MODE OVERVIEW Top limit Bottom limit T...

Страница 21: ...must be in Vertical Drop mode before switching between lock modes Press P2 on controller Press STOP on controller Press DOWN on controller AUTO MODE E TYPE MODE MANUAL MODE Motor Response Motor Respon...

Страница 22: ...op limit Press UP on controller Press DOWN on controller LOCK UNLOCK 6 4 3 Manual Mode Operation Motor Response Shade moves DOWN to release the Locking device then pauses Shade moves UP to the top lim...

Страница 23: ...set The use of a standard 1 part drive adapter is compatible The Impact Detection feature only works in the active zone during downward movement This impact detection feature is deactivated by default...

Страница 24: ...troller A Press P2 on controller A Press P2 on the controller B to remove it Press STOP on an new controller to add it Motor Response Motor Response Motor Response Motor Response Motor Response Motor...

Страница 25: ...te position Press P2 on controller Press STOP on controller Press STOP on controller Move shade to the desired position by pressing the UP or DOWN button on the controller Press P2 on controller Press...

Страница 26: ...Mode Method 1 Exit sleep mode once the shade is ready Exit Sleep Mode Method 2 Remove power and then re power the motor Motor Response 9 SLEEP MODE 10 WIND SENSOR FUNCTION Approx Once the motor receiv...

Страница 27: ...istance is to far from transmitter Move transmitter to a closer position Power failure Check power supply to motor is connected and active Incorrect wiring Check that wiring is connected correctly ref...

Отзывы: