background image

| Automate

 Programming Instructions | Motion Sensor 

ROLLEASE ACMEDA

STATIC TITLE

When battery voltage is lower than 2.3 V, it beeps every 5 seconds.

Adjust sensitivity accordingly. The detected vibration range is 3G. (1G = 9.8 m/s

2

)

High sensitivity could cause awning to react under slight wind.

If the disc magnet is dislodged, the vibration detection and low battery alarm functions are invalid.

• 

Dial Set to 0: Sensor is in pairing mode. Use P2 to pair to motor with existing pre-paired remote.

• 

Dial Set to 1-9: In Active mode, sensitivity, Highest - Lowest.

• 

Dial set to 5: Move motor to upper limit/Motion Sensor in Active mode.

• 

Dial set to 9: Move motor to bottom limit/ Motion Sensor in Inactive mode.

1.  Set Sensitivity Dial to zero

2.  Pair or unpair a motor to the sensor 

using a pre-paired remote

3.1  SENSITIVITY DIAL / P2 OPERATION

3.2  PAIRING TO MOTION SENSOR

= Existing controller or channel (to keep)

B

 = Motion Sensor to add or remove

Press 

P2

 on 

controller A.

Press 

P2

 on 

controller A.

Press 

P2

 on 

Motion Sensor 

B to add or 

remove.

Response

Response

Response

NOTE:

• 

The ARC Motion Sensor can only be connected and paired to External Motors (15Nm and above).

• 

After the sensor is paired to a motor, it can independently drive the motor without the remote.

3 FUNCTION

Содержание AUTOMATE ARC Motion Sensor

Страница 1: ...rotection from excessive wind gusts 9 x levels of sensitivity Low battery warning The ARC Motion Sensor is used to detect motion on a shade The result of strong vibration can trigger a paired awning m...

Страница 2: ...ctive Mode 7 3 5 Inactive Mode 7 4 TROUBLE SHOOTING 8 5 91in 150mm 4 21in 107mm 4 53in 115mm 1 4 3 2 8 5 6 7 REV ITEM NO DESCRIPTION QTY 1 Motion Sensor Cover 1 2 Motion Sensor Bracket 1 3 Motion Sens...

Страница 3: ...g interference that may cause undesired operation Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux c...

Страница 4: ...53in 115mm 1 4 3 2 8 REV DESCRIPTION DRAWN DATE C ROLLEASE ACMEDA DIMENSIONS IN MM SCALE 1 1 SIZE A3 PROPRIETARY CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ROLLEASE...

Страница 5: ...Motion Sensor ROLLEASE ACMEDA 0 1 2 3 8 7 4 9 6 5 0 1 2 3 8 7 4 9 6 5 0 1 2 3 8 7 4 9 6 5 0 1 2 3 8 7 4 9 6 5 Sensitivity dial Motion Sensor Cradle P2 0 1 2 3 8 7 4 9 6 5 2 4 SENSITIVITY DIAL ADJUSTM...

Страница 6: ...sitivity Highest Lowest Dial set to 5 Move motor to upper limit Motion Sensor in Active mode Dial set to 9 Move motor to bottom limit Motion Sensor in Inactive mode 1 Set Sensitivity Dial to zero 2 Pa...

Страница 7: ...e remote emits two beeps In this mode the motion sensor will not trigger the shade to move The sensor can still be used as a remote to move the shade up or down 3 4 ACTIVE MODE 3 5 INACTIVE MODE Respo...

Страница 8: ...way from metal Receiver distance is too far from transmitter Move sensor to a closer position Power failure Check power supply to motor is connected and active Incorrect wiring Check wiring is connect...

Отзывы: