Maintenance
When Problems Such As Dot Drop-out are Not Cleared Up
73
Cleaning of the head surface as an emergency measure
When dot drop-out and/or dot deflection is not improved even if cleaning is performed several times,
you can clean the head surface as an emergency measure. Since the head surface (nozzle surface) has
an extremely delicate mechanism, make sure to perform the operation carefully and deliberately.
Note that this operation is an emergency measure. It may damage defect-free parts depending on
the symptom, deteriorating it. If you have any questions, contact your authorized Roland DG Corp.
dealer.
Procedure
Moisten the cleaning stick with the cleaning liquid.
Softly press the cleaning stick to the head surface (nozzle surface).
Press it gently and softly so that the head nozzle is permeated with the cleaning fluid.
Never rub the stick on the surface and press it forcibly.