7.2
Measuring operation
After powering up, the system automatically switches over to the measuring operation.
Screen area
1: Visualization of the sensor
signal (original signal und
digitally filtered signal) and
a control signal.
Indication of
weld seam width
according to entry
“
weld seam width [%]
”.
2: List of measuring results.
3: List of parameters of the
activated measuring
program.
4: Indication of program status
and operation condition,
see chapter ”
Maintenance
and repair
“.
Fig. 37: Measuring operation
Changes over to the program
selection.
Prints out the signal visualization and a
list of the program parameters.
Changes over to the system
parameter selection.
No key function in this mode.
Changes over to the statistics
function.
Selects the parameters from the list.
No key function in this mode.
Note:
The result of the weld seam detection is stated in dB (signal amplitude within the
weld seam vs. signal amplitude outside the weld seam).
Note:
Starting with firmware version V23 following behaviour has been observed: At a
data amount of 5000 values per rotation the signal transmission is suspended. In
the display only a horizontal line appears. To avoid this, the parameter "sample
rate" can be set to a lower value, for example to 30.