41
XY-RS-34/14 cable connection
D-sub 9 pin
D-sub 25 pin
Serial connector (RS-232C)
NC
NC
NC
NC
NC
DTR
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
SG
DSR
CTS
RTS
RXD
TXD
FG
Terminal
number
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Pin connection
Signal
number
Signal
number
3. Specifications
Table size
Diameter 254 mm (10 in.)
Maximum scanning area
Rotary scanning: Diameter 254 mm (10 in.), height 406.4 mm (16 in.)
Plane scanning: Diameter 230 mm (9 in.), height 406.4 mm (16 in.)
Scanning pitch
Rotary scanning: circumference 0.2 to 60 degrees, height direction 0.2 to 406.4 mm
Plane scanning: width direction 0.2 to 230 mm, height direction 0.2 to 406.4 mm
Maximum table load weight
5 kg (11 lb.) (not including optional vise)
Laser
Wavelength: 600 to 700 nm, maximum output: less than 1.0 mW (maximum output discharged outside
housing is 0.39
µ
W), pulse width: 350
µ
s, pulse frequency: 2,857 Hz
Sensor
Noncontact laser sensor
Scanning method
Spot-beam triangulation
Operating speed
Table rotation speed: 15 rpm, head rotation speed: 7.5 rpm, head movement speed: 50 mm/sec.
Interface
Serial (RS-232C standard, D-Sub 25 pin)
Transfer method: Asynchronous/full duplex data communication, 9,600/115,200 bps transfer speed,
8 data bits, 1 stop bit, no parity, hardware flow control
Control keys and LEDs
Standby key, Standby LED, and Movement LEDs
Power consumption
Dedicated AC adapter (DC 19 V, 2.1 A)
External dimensions
528 (W) x 742 (D) x 431 (H) mm (20-13/16 (W) x 29-3/16 (D) x 16-15/16 (H) in.)
Weight
32 kg (70.5 lb.) (main unit only)
Operating temperature
10 to 40 ˚C (50 to 104 ˚F)
Operating humidity
35 to 80% (no condensation)
included items and accessories
AC adapter: 1, power cord: 1, 2.5-mm hexagonal wrench: 1, 3-mm hexagonal wrench: 1, caps: 3,
Roland Software Package CD-ROM: 1, user's manual: 1, Roland Pixform™: 1
2. Table Dimensional Drawing 3. Specifications