Roland PDX-8 Скачать руководство пользователя страница 2

*

4

0

6

7

3

8

5

6

-

0

2

*

PDX-8 LEAFLET Trigger Parameter

Copyright © 2006  ROLAND CORPORATION

All rights reserved. No part of this publication may be reproduced in any 
form without the written permission of ROLAND CORPORATION.

40673856          2PD

For PDX-8 Owners

Read This First

Use of the setup without the following may prevent the PDX-8’s rim shots from sounding, 
cause double triggering, or result in other problems.

For the PDX-8 function correctly, the trigger parameters in your percussion sound module (TD-3, 
TD-6, TD-12, TD-20, etc.) must be adjusted.

If you find the following kinds of problems occurring, adjust the “Rim Sensitivity.”

• If you cannot get a rim sound even when you strike the rim hard, increase the “Rim Sens” value.
• If you hear a rim sound when you strike the head, decrease the “Rim Sens” value.

1. Tune the Head

2. Make the Settings for the Trigger Parameters

3. Adjust the “Rim Sensitivity” 

(*1: See below)

Example: Connect the PDX-8 to the Trigger Input 2 (SNARE) on the TD-6V

How To Set the Trigger Parameters

1.

Press [SHIFT] + [EDIT (SETUP)] on the TD-6V.

2.

Strike the head of the PDX-8.

The trigger input 2 (SNARE) is selected.

3.

Press [

] to select “TRIG BASIC” or “TRIG ADVNCD.”

4.

Press [ENTER

].

5.

Press [

] or [

] to select the parameter (“TrigTyp”, “Mask Time”, “Rim Sens”, etc.).

6.

Press [+] or [-] to make the setting.

7.

Press [KIT]; the [EDIT (SETUP)] light goes off.

Trigger Parameter

Value

Trigger Basic
(TRIG BASIC)

Trigger Type
(TrigTyp)

PD-80R

Trigger Advanced
(TRIG ADVNCD)

Mask Time

8ms

Rim Sens

13 (8–15)

 (*1)

1

Example: Connect the PDX-8 to the SNARE input on the TD-3

How To Set the Trigger Parameters

1.

Press [LEVEL/PAN] + [TEMPO] on the TD-3.

[EDIT] flashes and “

” appears in the display, then the trigger type value is indicated.

2.

Strike the PDX-8.

The SNARE trigger indicator lights.

3.

Press [EDIT] to select the parameter (“

”, “

”, “

”, “

”, etc.).

4.

Press [+] or [-] to make the setting.

5.

Press [DRUM KIT]; the [EDIT] light goes off.

* Do not turn off the power without the [EDIT] light having gone out. Otherwise you will lose the change you have just made.

Trigger Parameter

Display

Value

Trigger Type

80r

Mask Time

8

Rim Sensitivity

12 (7–16) 

 (*1)

Rim Gain

1.5

1

Отзывы: