Roland GR-S Скачать руководство пользователя страница 10

Setting

10

Adjust the Pickup Sensitivity

If you feel that the volume balance between the 

strings is incorrect or the sound is unnaturally 

distorted, check the way in which the GK pickup is 

attached.

Check

 

Is the GK-pickup correctly installed?

• 

After reading the instructions in the GK-pickup Owner’s 

Manual, check the installation once more.

• 

On the Roland website, the 

“How to install the GK pickup” 

page provides an explanation and photos on how to attach 

a GK pickup. Be sure to take a look!

http://www.roland.com/GK/

If this does not solve the problem, you can adjust the 

pickup sensitivity as described below. 

Normally, you should use the factory settings.

1. 

While holding down the [SELECT] 

button, turn on the power (insert a plug 

into the OUTPUT L jack).

The unit will be in pickup sensitivity adjustment mode.

2. 

Press the [ON/OFF] pedal to select a 

string.

Start by selecting string 1.

String Indicator

1

ON/OFF

FREEZE

POWER

GR-S

2

ON/OFF

FREEZE

POWER

GR-S

3

ON/OFF

FREEZE

POWER

GR-S

4

ON/OFF

FREEZE

POWER

GR-S

5

ON/OFF

FREEZE

POWER

GR-S

6

ON/OFF

FREEZE

POWER

GR-S

3. 

Play a string, and use the [TONE] knob to 

adjust the Pickup Sensitivity.

Sensitivity

Indicator

1 (low)

1

2

3

4

2

1

2

3

4

3

1

2

3

4

4

1

2

3

4

5

1

2

3

4

6

1

2

3

4

7

1

2

3

4

8 (high)

1

2

3

4

The MEMORY indicator shows the current 

sensitivity setting.

Play string 1 at the maximum 

strength you would use during 

actual performance, and use the 

[TONE] knob to adjust the sensitivity 

so that the MANUAL indicator lights 

briefly at the maximum volume.

If the sound is unnaturally distorted, lower the sensitivity.

4. 

In the same way, adjust the sensitivity 

for the 2nd through 6th strings as well.

5. 

Check the volume balance of the six 

strings.

Play each of the strings 6–1 at normal strength; if a string 

sounds unusually loud, lower the sensitivity of that string to 

minimize any discrepancy in volume between the strings.

6. 

Press the [WRITE] button to decide the 

setting.

What is Pickup Sensitivity?

Cutaway diagram of the guitar neck

GK-pickup

If the distance between each string and the GK pickup 

is different, the volume will also be different. The pickup 

sensitivity adjustment allows you to compensate for this 

difference in volume.

Содержание GR-S

Страница 1: ...ue holding down it down for five seconds p 9 Before using this unit carefully read the sections entitled USING THE UNIT SAFELY and IMPORTANT NOTES supplied on a separate sheet These sections provide important information concerning the proper operation of the unit Additionally in order to feel assured that you have gained a good grasp of every feature provided by your new unit Owner s manual shoul...

Страница 2: ... sound selection during your live performances Check the following points before using the GR S You ll need a GK compatible guitar In order to use the GR S you ll need a guitar equipped with a GK pickup or a GK compatible guitar such as the GC 1 V Guitar Hereafter we ll refer to such a guitar as a GK compatible guitar The GR S does not support basses GK 3B You must set the GK pickup select switch ...

Страница 3: ...flush them thoroughly Then promptly see a doctor Burning of the skin or dermatitis may result if fluid has gotten onto your skin or clothing Use clean water to flush affected areas thoroughly then promptly see a doctor Using a soft cloth carefully wipe any remaining fluid from the inside of the battery compartment Then install new batteries Notes Concerning Batteries When operating on battery powe...

Страница 4: ... use of the stored settings For details refer to Selecting the MANUAL MEMORY p 8 WRITE button Press this to store settings in MEMORY For details refer to Storing the MEMORY p 8 TYPE buttons Selects the effect type TYPE buttons COLOR knob TONE knob 1 CRYSTAL A sound with a metallic resonance and a transparent character Adjusts the tonal character of the high frequency range Turning the knob toward ...

Страница 5: ...jacks are connected to a guitar amp G AMP or to a line level device LINE The OUTPUT L jack also operates as a power switch The power will be on if a plug is inserted in the OUTPUT L jack Remove the plug when you re not using the GR S To prevent malfunction and equipment failure always turn down the volume and turn off all the units before making any connections Guitar Amp When connecting to the gu...

Страница 6: ...normal and does not indicate a malfunction Application Examples Connecting another effects unit following the GR S Guitar Amp Recorder or Mixer Effect Device Effect Device GK compatible guitar GK compatible guitar Using in combination with other effect devices send return OUTPUT INPUT When connecting to the recorder or mixer set the SELECT switch to LINE When connection cables with resistors are u...

Страница 7: ...rately to switch between playing the GR S and GR D or playing both simultaneously using a single guitar Two GK cables 1 2 meters are included with the US 20 GK IN GK IN OUTPUT US 20 GR 55 Recorder or Mixer GK compatible guitar When connecting to the recorder or mixer set the SELECT switch to LINE If the sound of the GR 55 is unnaturally distorted reduce the volume of the GR 55 ...

Страница 8: ...TE button The indicator for the currently selected MEMORY number start to flash and the GR S is put into write standby 3 Press the SELECT button to select the MEMORY number to which you want to store the sound The indicator for the selected MEMORY number flashes 4 Press the WRITE button The write operation is completed after the indicator for the write destination memory flash more rapidly To canc...

Страница 9: ...conds the GR S will resume normal operation sleep mode will be enabled Restoring the Factory Settings Factory Reset Here s how to restore the GR S s settings to their factory set condition When you execute Factory Reset the settings you made will be lost 1 While holding down the WRITE button turn on the power insert a plug into the OUTPUT L jack All MEMORY indicators 1 4 will blink 2 Press the WRI...

Страница 10: ...EEZE POWER GR S 5 ON OFF FREEZE POWER GR S 6 ON OFF FREEZE POWER GR S 3 Play a string and use the TONE knob to adjust the Pickup Sensitivity Sensitivity Indicator 1 low 1 2 3 4 2 1 2 3 4 3 1 2 3 4 4 1 2 3 4 5 1 2 3 4 6 1 2 3 4 7 1 2 3 4 8 high 1 2 3 4 The MEMORY indicator shows the current sensitivity setting Play string 1 at the maximum strength you would use during actual performance and use the...

Страница 11: ...e necessary signals may not be input to the unit which may prevent sounds from being produced Is the GK pickup s GK Volume turned down Check to make sure the GK pickup s GK Volume is not lowered Is the GK pickup correctly installed and connected After reading the instructions in the GK pickup Owner s Manual check the installation once more Noise is produced Is the external device connected to the ...

Страница 12: ...LATION SLOW PAD BRILLIANT CLEAN Power Supply Alkaline battery AA LR6 or Carbon zinc battery AA R6 x 6 AC Adaptor PSA series optional Current Draw 200 mA 9 V when used with GK 3 Expected Battery Life Under Continuous Use Alkaline battery Approx 7 hours Carbon zinc battery Approx 2 hours These figures will vary depending on the actual conditions of use Dimensions 173 W x 158 D x 57 H mm 6 13 16 W x ...

Отзывы: