43
Chapter 6 Appendices
❍
General Purpose #3
STATUS
SECOND
THIRD
BnH
12H
vvH
n=MIDI Channel Number:
0H - FH (ch.1 - ch.16)
vv=Control Value:
00H - 7FH (0 - 127)
*
Transmitted the envelope data of the strings when “E FLW” is on.
*
Data is sent only in Mono mode. Transmission doesn’t take place in Poly mode.
❍
Hold1
STATUS
SECOND
THIRD
BnH
40H
vvH
n=MIDI Channel Number:
0H - FH (ch.1 - ch.16)
vv=Control value:
00H - 7FH (0 - 127)
01H-3FH=OFF, 40H-7FH=ON
*
Transmitted the operation of HOLD TYPE = “H4”.
❍
RPN MSB/LSB
STATUS
SECOND
THIRD
BnH
65H
mmH
BnH
64H
llH
n=MIDI Channel Number:
0H - FH (ch.1 - ch.16)
mm=Upper byte of the parameter data designated by RPN
ll=Lower byte of the parameter data designated by RPN
<<< RPN >>>
Control change includes RPN(registered parameter number), function which are defined by
the MIDI standard.
The GR-20 can transmit only one RPN: pitch bend sensitibity(RPN#0).
RPN
Data entry
MSB LSB
MSB LSB
Function
00H 00H
18H 00H
pitch bend sensitivity
●
Program change
STATUS
SECOND
CnH
ppH
n=MIDI Channel Number:
0H - FH (ch.1 - ch.16)
pp=Program Number:
00H - 7FH (prg.1 - prg.128)
*
The recognized Program Change Number corresponds to each patch as follows.
BANK MSB
PROGRAM NUMBER
PATCH
0
0
USER 1
0
1
USER 2
0
2
USER 3
0
3
USER 4
0
:
:
0
97
USER 98
0
98
USER 99
1
0
PIANO 1
1
1
PIANO 2
1
2
PIANO 3
:
:
2
0
ORGAN/KB 1
2
1
ORGAN/KB 2
2
2
ORGAN/KB 3
:
:
3
0
BASS/GTR 1
3
1
BASS/GTR 2
3
2
BASS/GTR 3
:
:
4
0
BRASS 1
4
1
BRASS 2
4
2
BRASS 3
:
:
5
0
WIND 1
5
1
WIND 2
5
2
WIND 3
:
:
6
0
STRING/ORCH 1
6
1
STRING/ORCH 2
6
2
STRING/ORCH 3
:
:
7
0
SYNTH/LEAD 1
7
1
SYNTH/LEAD 2
7
2
SYNTH/LEAD 3
:
:
8
0
VOICE/PAD 1
8
1
VOICE/PAD 2
8
2
VOICE/PAD 3
:
:
9
0
ETHNIC 1
9
1
ETHNIC 2
9
2
ETHNIC 3
:
:
10
0
RHYTHM/PERC 1
10
1
RHYTHM/PERC 2
10
2
RHYTHM/PERC 3
:
:
●
Pitch Bend Change
STATUS
SECOND
THIRD
EnH
llH
mmH
n=MIDI Channel Number:
0H - FH (ch.1 - ch.16)
mm,ll=Value:
00H, 00H - 7FH, 7FH (-8192 - +8191)
■
System Realtime Message
❍
Active Sensing
STATUS
FEH
*
This message is always transmitted at about 270msec’ interval.
❍
System Exclusive message
STATUS
SECOND
THIRD
F0H
iiH,ddH,.....,eeH
F7H
F0H:
System Exclusive
ii=ID Number:
41H (65)
dd,...,ee=Data:
00H-7FH (0-127)
F7H:
EOX (End of Exclusive/System Common
Message)
*
For more details, refer to the page “Roland exclusive message” and Section3 or after.
3. Exclusive Communications
The GR-20 can transmit or receive system and patches parameters using system exclusive
messages. Model ID of exclusive message available on the GR-20 is 00H 72H.Device ID is
fixed at 10H.
When the GR-20 receives an Identify Request inquiry message, it will transmit an Identity
Reply.
GR-20_e.book 43 ページ 2007年7月2日 月曜日 午後12時53分