Page 21
Refrigerant charging
Procedure:
1.
Connect the charge hose to the 3-way service port
and then open the 2- and the 3-way valves.
2.
Connect the charge hose to the valve at the bo
�
om
of the cylinder.
3.
If the refrigerant is R410A, invert the cylinder to
ensure a complete liquid charge.
4.
Open the valve at the bo
�
om of the cylinder and close
the check valve on the charge set to purge the air.
5.
Place the charging cylinder onto an electronic scale
and record the star
�
ng weight.
6.
Operate the air condi
�
oner in cooling mode.
7.
Open the valves (Low side) on the charge set and
charge the system with liquid refrigerant.
8.
When the electronic scale displays the correct weight
(refer to the gauge and the pressure of the low side
to con
fi
rm), disconnect the charge hose from the
3-way valve’s service port immediately and turn o
ff
the air condi
�
oner before disconnec
�
ng the hose.
9.
Mount the valve stem caps and the service port.
10.
Use a torque wrench to
�
ghten the service port cap to
a torque of 18 N.m.
11.
Check for gas leakage.
Note: 1. Mechanical connectors used indoors shall comply with local regula
�
ons.
2. When mechanical connectors are reused indoors, sealing parts shall be renewed. When
fl
ared joints
are reused indoors, the
fl
are part shall be re-fabricated.
+RKIZXUTOI YIGRK
(/TJUUX [TOZ)
(2OW[OJ YOJK)
(5[ZJUUX [TOZ)
:]U-]G_ \GR\K
5VKT
(-GY YOJK)
)NKIQ \GR\K
:NXKK-]G_ \GR\K
5VKT
)NGXMOTM
I_ROTJKX
2U
.O
56+4
)259+
M
ai
n
te
n
a
n
c
e
a
nd
D
is
a
ss
e
m
b
ly
Содержание FAVORITE ON-OFF Series
Страница 1: ...FAVORITE Service Manual 2019 ON OFF Series...
Страница 3: ......
Страница 5: ......
Страница 79: ...Page 76 Contents i Temperature Sensor Resistance Value Table for T1 T2 T3 and T4 C K 77...