About Placement

 

If using commercially available Cat5e Ethernet cables, attach the supplied REAC 
connector covers to the connectors.

Attach the rubber feet when not rack mounting the unit.

Peel off the backing from the double-sided adhesive tape on the rubber feet and 
attach the feet at the points indicated in the figure below.

 

928

 

* When turning the unit upside-down, get a bunch of newspapers or magazines, and place 

them under the four corners or at both ends to prevent damage to the buttons and controls. 
Also, you should try to orient the unit so no buttons or controls get damaged.

 

929

 

* When turning the unit upside-down, handle with care to avoid dropping it, or allowing it to 

fall or tip over.

 

Using the REAC Connector Covers

Attaching the Rubber Feet

Remove the REAC connector 
covers if you are using REAC 
cables with EtherCon type 
connectors (SC-W100X or SC-
W100S).
Take care not to lose the REAC 
connector covers removed at 
this time.

bottom of the unit

S-4000-SP_e.book 11 ページ 2006年8月24日 木曜日 午前10時33分

Содержание digital snake S-4000-SP

Страница 1: ...wer to each of the two internal splitters enabling uninterrupted use in the event the power happens to cut out in one of the power supplies or if there is some other sort of power interruption 201b Be...

Страница 2: ...nto your outlet consult an electrician for replacement of the obsolete outlet WARNING IMPORTANT As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured mar...

Страница 3: ...d from the outlet and request servicing by your dealer the nearest Roland Service Center or an authorized Roland distributor as listed on the Information page when The power supply cord or the plug ha...

Страница 4: ...it 103a At regular intervals you should unplug the power plug and clean it by using a dry cloth to wipe all dust and other accumulations away from its prongs Also disconnect the power plug from the po...

Страница 5: ...rom happening If you do so please make sure that the unit will not slip or move accidentally Maintenance 401a For everyday cleaning wipe the unit with a soft dry cloth or one that has been slightly da...

Страница 6: ...the Rack Mount Brackets 10 Using the REAC Connector Covers 11 Attaching the Rubber Feet 11 Notes to Observe in Using the S 4000 System 12 Use and Handling of REAC Systems 12 About REAC Cables 12 Notes...

Страница 7: ...way as those for the MAIN REAC ports 1 5 POWER Indicators A B These indicate the status of the power supply The corresponding indicator lights blue when power is supplied from AC INPUT A or B on the...

Страница 8: ...REAC BACKUP enabling continuous use even when circumstances result in an interruption of power in one of the systems 921 To prevent malfunction and or damage to speakers or other devices always turn...

Страница 9: ...e ordinary power supply is available Connect AC INPUT A to an ordinary power outlet Connect AC INPUT B to the external backup power supply Use the following procedure to secure the power plugs 1 Inser...

Страница 10: ...the rack when you have plugs connected Use the following procedure to remove and reinstall the S 4000 UP s rack mount brackets for recessed rack mounting 1 Turn off the power on all equipment and disc...

Страница 11: ...apers or magazines and place them under the four corners or at both ends to prevent damage to the buttons and controls Also you should try to orient the unit so no buttons or controls get damaged 929...

Страница 12: ...used for REAC connections conform to the Cat5e Ethernet Category 5 standard No single cable should be longer than 100 meters Do not use cables with cut or torn coverings Do not subject cables to undue...

Страница 13: ...le then the system will not automatically switch to the BACKUP REAC system cables and Reestablishing Transmission Carry out the following steps in the event a transmission failure to the split device...

Страница 14: ...mic line sources from stage 8 outputs from console Cat5e cable in a redundant system for each Cat5e line in diagram Cat5e cables S 4000S 32x8 Master REAC device 32 mic line sources from the stage 8 ou...

Страница 15: ...AC 230 V AC 240 V 50 60 Hz Power Consumption 13 W Dimensions 482 0 W x 224 8 D x 43 8 H mm 19 W x 8 7 8 D x 1 3 4 H inches Weight 2 8 kg 6 lbs 3 oz Operation Temperature 0 to 40 degrees centigrade 32...

Страница 16: ...U S 425 Sequoia Drive Suite 114 Bellingham WA 98226 360 594 4282 Information When you need repair service call your nearest Roland Service Center or authorized Roland distributor in your country as s...

Отзывы: