16
Jul. 2007
AC-90
12.
[Foot SW 2] jack switch
• Detaching the plug from [Foot SW 1] on the AC-90 makes the [ANTI-
FEEDBACK] and [MUTE] LEDs go dark.
• Inserting a plug into [Foot SW 2] on the AC-90 makes the following LEDs
light up.
GUITAR channel [CHORUS] LED
MIC/LINE channel [CHORUS] LED
[ANTI-FEEDBACK] LED
[MUTE] LED
13.
[Foot SW 2] [TIP] switch
Depressing the [TIP] (white) foot switch makes the [ANTI-FEEDBACK]
LED go dark.
14.
[Foot SW 2] [RING] switch
Depressing the [RING] (red) foot switch makes the [MUTE] LED go dark.
15.
[PHONES] jack switch
• Detaching the plug from [Foot SW 2] on the AC-90 makes the GUITAR
channel and MIC/LINE channel [CHORUS] LEDs go dark.
• Inserting headphones into [PHONES] makes the following LEDs light
up.
GUITAR channel [CHORUS] LED
MIC/LINE channel [CHORUS] LED
[ANTI-FEEDBACK] LED
[MUTE] LED
• Detaching the headphones plug inserted into [PHONES] makes the
following LEDs go dark.
GUITAR channel [CHORUS] LED
MIC/LINE channel [CHORUS] LED
[ANTI-FEEDBACK] LED
[MUTE] LED
* If an error is made in the inspection-test sequence, or of a test is failed, execution
cannot advance to the next test.
• When all switch testing are completed, the following LEDs flash.
GUITAR channel [CHORUS] LED
MIC/LINE channel [CHORUS] LED
[ANTI-FEEDBACK] LED
[MUTE] LED
• Insert a PCS-31 plug into [Foot SW 1] on the AC-90 and depress the [TIP]
(white) foot switch to make execution advance to the next inspection test.
4. Volume Control Test
When the volume-control test is begun, the following LEDs go dark.
GUITAR channel [CHORUS] LED
MIC/LINE channel [CHORUS] LED
[ANTI-FEEDBACK] LED
[MUTE] LED
• Operating the volume knob makes self-oscillation by the DSP start, and
audio is output from the speakers.
• Until the inspection test for a single volume control ends, the volume
level changes according to the position of the control knob.
• In testing the volume controls, verify the change from minimum to center
and from center to maximum, and be sure to go on to testing of the next
volume knob while leaving the first one at maximum.
• Perform testing of the volume controls in this sequence: [MASTER] =>
[CHORUS] => GUITAR channel [TREBLE] => GUITAR channel
[MIDDLE] => GUITAR channel [BASS] => GUITAR channel [VOLUME]
=> MIC/LINE channel [VOLUME] => MIC/LINE channel [BASS] =>
MIC/LINE channel [MIDDLE] => MIC/LINE channel [TREBLE] =>
[REVERB/DELAY] => [FREQUENCY].
fig.VR-test.eps
• When the “minimum” setting of the volume control is detected, the
[ANTI-FEEDBACK] and [MUTE] LEDs go dark.
• When the “center” setting of the volume control is detected, the [ANTI-
FEEDBACK] LED lights up.
• When the “maximum” setting of the volume control is detected, the
[ANTI-FEEDBACK] and [MUTE] LEDs light up.
* If a failed test occurs before inspection of the volume controls finishes, execution
cannot advance to testing of the next volume control.
• When the tests for all volume controls have been passed, the following
LEDs flash.
GUITAR channel [CHORUS] LED
MIC/LINE channel [CHORUS] LED
[ANTI-FEEDBACK] LED
[MUTE] LED
• Switch off the power.
5. Phantom Voltage Test
• Switch on the power.
• Adjust the [MASTER] volume knob to minimum.
• The settings of the other switches and volume controls are unspecified
(not relevant).
• Using the tester, check the DC voltage between each MIC/LINE channel
[INPUT] XLR terminal.
• Set the measurement range on the tester to 50 V or higher.
• Bring [COM] (black) on the tester into contact with the [1: GND]
terminal.
1. [PHANTOM] OFF Voltage
• Set the [PHANTOM] switch to OFF.
• Bring the tester’s [+] probe (red) into contact with the [2: HOT] connector
and verify that the voltage is near 0 V.
• Bring the tester’s [+] probe (red) into contact with the [3: COLD]
connector and verify that the voltage is near 0 V.
2. [PHANTOM] ON Voltage
• Set the [PHANTOM] switch to ON.
• Bring the tester’s [+] probe (red) into contact with the [2: HOT] connector
and verify that a voltage of 44 to 49 V is output.
• Bring the tester’s [+] probe (red) into contact with the [3: COLD]
connector and verify that a voltage of 44 to 49 V is output.
Содержание AC-90 Acoustic Chorus
Страница 4: ...4 Jul 2007 AC 90 Location of Controls fig panel eps...
Страница 13: ...13 Jul 2007 AC 90...
Страница 20: ...Jul 2007 AC 90 Block Diagram Wiring Diagram fig AC90 block eps L 21 20...
Страница 21: ...Jul 2007 AC 90 23 Circuit Board Main XLR Board fig AC90 pcb main 01 eps L 22...
Страница 22: ...Jul 2007 AC 90 25 Circuit Diagram Main Board Digital fig AC90 sch main digital eps L 24...
Страница 23: ...Jul 2007 AC 90 27 Circuit Diagram Main Board Analog XLR Board fig AC90 sch main analog eps L 26...
Страница 24: ...28 Jul 2007 AC 90 Circuit Diagram Main Board Power Supply fig AC90 sch main power Sup eps...
Страница 25: ...29 Jul 2007 AC 90...
Страница 26: ...Jul 2007 AC 90 31 Circuit Board Jack Board fig AC90 pcb jack borad 01 eps L 30...
Страница 27: ...Jul 2007 AC 90 33 Circuit Diagram Jack Board fig AC90 sch main jackborad eps L 32...
Страница 28: ...Jul 2007 AC 90 35 Circuit Board Panel Board fig AC90 pcb panel 01 eps L 34...
Страница 29: ...Jul 2007 AC 90 37 Circuit Diagram Panel Board fig AC90 sch main panel eps L 36...
Страница 30: ...38 Jul 2007 AC 90 Circuit Board PS1 Board fig AC90 pcb PS1 eps...
Страница 31: ...39 Jul 2007 AC 90 Circuit Diagram PS1 Board fig AC90 sch main power eps...
Страница 32: ...40 Jul 2007 AC 90 Circuit Board Amp Board fig AC90 pcb amp 01 eps...
Страница 33: ...41 Jul 2007 AC 90 fig AC90 pcb amp 02 eps...
Страница 34: ...Jul 2007 AC 90 43 Circuit Diagram Amp Board fig AC90 sch amp eps L 42...
Страница 35: ...MEMO Jul 2007 AC 90...