background image

- 3 - 

TABLE OF CONTENTS 

Introduction and Definitions of Safety Warnings 

Safety Warnings – Risk of Asphyxiation, Bursting,  Electrocution,  
            Shock, Explosion or Fire 

Safety Warnings – Risk of Moving Parts, Burns, Injury from Lifting,  
            Propelled Objects, Unsafe Operation and Damage to  
            Compressor or Property 

Identification of System Controls 

6-7 

Pre-Start Checklist 

7-8 

Specifications  

Operation 9 
Maintenance 9-10 
Troubleshooting 10 
Guarantee 11 
Schematics – JC10 

12-13 

                      JC13 

14-15 

 

INTRODUCTION 

Congratulations on the purchase of your new ROLAIR

®

 air compressor!   

 
With over 50 years experience building ROLAIR

®

 air compressors specifically designed for the professional, 

Associate Engineering Corporation has earned a reputation for providing a product unsurpassed in quality 
and reliability.  We are committed to continuing this tradition by analyzing and adapting to the changing 
needs and rigorous demands of your industry.  You can depend on ROLAIR

®

 because they are built to last.   

 
This manual was compiled for the benefit of the operator.  Do not use or allow anyone else to use your air 
compressor until this manual is read and all safety/operating instructions are understood.  By reading and 
following the instructions contained in this manual, you can achieve years of trouble free service from your 
new air compressor.  If you have any additional safety or operating questions after reading this manual, 
please contact your distributor or our customer service department.  Do not remove or paint over any of 
the warning decals attached to the compressor. 
 

Definitions – Safety Warnings 

Safety symbols are used throughout this manual to alert you to potentially hazardous situations.  The 
following definitions describe the level of severity for each signal word. 
 

  DANGER: 

Indicates an imminently hazardous situation which, if not avoided, WILL result in death 

 

 

or serious injury. 

 

  WARNING: 

Indicates a potentially hazardous situation which, if not avoided,  COULD result in  

 

 

death or serious injury. 

 

  CAUTION: 

Indicates a potentially hazardous situation which, if not avoided,  MAY result in minor  

 

 

or moderate injury or damage to the air compressor. 

 

 

Содержание JC10

Страница 1: ... 1 PORTABLE AIR COMPRESSOR OWNER S MANUAL MODEL JC10 JC13 SERIAL NUMBER __________________ 606 South Lake Street P O Box 346 Hustisford WI 53034 0346 920 349 3281 fax 920 349 3691 www rolair com ...

Страница 2: ... With the tank gauge at 0 PSI and air line s disconnected close drain valve s and record the amount of time it takes to build tank pressure on the space provided Periodically test your air compressor against this pump up time to determine if it is operating correctly If time test is considerably off contact your local ROLAIR representative to arrange service From 0 to ______ PSI From 0 to ______ P...

Страница 3: ...ilt to last This manual was compiled for the benefit of the operator Do not use or allow anyone else to use your air compressor until this manual is read and all safety operating instructions are understood By reading and following the instructions contained in this manual you can achieve years of trouble free service from your new air compressor If you have any additional safety or operating ques...

Страница 4: ...t use air tools or attachments before reading the owner s manual to determine the maximum pressure recommendations Never exceed the manufacturer s maximum allowable pressure ratings Do not use compressor to inflate small low pressure objects such as toys Risk of Electrocution or Electrical Shock Serious injury or death could occur if the air compressor is not properly grounded Always plug compress...

Страница 5: ...heavy for one person Flying Objects Serious injury may occur from loose debris being propelled at high speeds from the compressed air stream Always wear OSHA required ANSI Z87 1 1989 safety glasses to protect the eyes during operation of the air compressor Never point the air stream or tools at any point of your body other people or animals Always turn off the air compressor and drain tank pressur...

Страница 6: ...and gauge length of extension cord being used whenever the overload causes the motor to stop running Refer to the chart on page 8 3 PRESSURE SWITCH Your air compressor operates by the use of a pressure switch Always make sure the lever is in the Off position before plugging in the power cord By moving the lever to the On Auto position the compressor will start and stop automatically within the set...

Страница 7: ...pressure If air leaks continuously from the solenoid after a cycle is complete there is a problem with the operation of the check valve item 8 12 COLD START VALVE The cold start valve allows the motor pump to warm up before building tank pressure When starting against zero PSI it releases only a portion of the air being compressed for approximately ten seconds and normally seals after the tank pre...

Страница 8: ... fittings will lead to excessive vibration and the premature failure of the compressor system control components 7 MAINTAIN RUBBER VIBRATION PADS Excessive vibration is a major cause of premature compressor failure Always maintain the rubber vibration pads located beneath tank assembly Operation without them will void your warranty 8 DRAIN MOISTURE FROM AIR TANK DAILY Water is a natural byproduct ...

Страница 9: ...d perform maintenance as indicated in manual NOTE Do not subject compressor to continuous use The JC series air compressors are rated for 70 duty cycle If operated for more than forty minutes per hour the motor will overheat and cause the internal overload to shut down the compressor The overload will also allow the motor to automatically restart after the motor has sufficiently cooled which can b...

Страница 10: ...ate power supply and duty cycle Capacitor has failed Replace and retest Motor runs but pump will not reach top pressure setting of 125 PSI Excessive external leaks at tank drain regulator hoses etc Use soap water solution to identify and correct leaks Broken valve blown gasket or other internal issue Inspect valve plates or take in for service Unit does not maintain tank pressure after stopping at...

Страница 11: ...nties of merchantability and fitness for purpose and of any other obligations and or liabilities on the part of Associate Engineering Corporation Associate Engineering Corporation neither assumes nor authorizes any other person to assume for it any other obligations or liability in connection with or with respect to any compressor Associate Engineering Corporation shall in no event be liable neith...

Страница 12: ... 12 ...

Страница 13: ... Nipple JC800 46 1 16 Valve Stop JC800 16 2 47 Safety Relief Valve JC800 47 1 17 Valve Exhaust JC800 17 2 48 Pressure Switch JC800 48 1 18 Valve Plate JC800 18 2 49 Capacitor JC800 49 1 19 Valve Intake JC800 19 2 50 Cover Capacitor JC800 50 1 20 Washer JC800 20 2 51 Check Valve JC800 51 1 21 Fan right side only JC800 21 1 52 Solenoid Unloader JC800 52 1 22 Eccentric JC800 22 2 53 Braided Discharge...

Страница 14: ... 14 ...

Страница 15: ...C800 58 4 19 Valve Intake JC800 19 2 59 Drain Valve JC800 59BV 1 20 Washer JC800 20 2 60 Cord with Plug JC800 60 1 21 Fan right side only JC800 21 1 63 Nut JC800 63 4 23 Bearing JC800 23 2 64 Rotor JC800 64 1 24 Setscrew JC800 24 2 65 Stator JC800 65 1 25 Bolt Con Rod JC800 25 2 66 Washer JC800 66 4 27 Box Connector JC800 27 1 67 Bolt JC800 67 4 28 Bolt JC800 28 2 68 Screw JC800 68 2 29 Bolt JC800...

Отзывы: