Multi-Use Hybrid Bio 3D Printer

Rokit Invivo as the most innovative and up to date bio 3D printer, allows users to create versatile 3D cellular 

structure with multi material and extensive designs. By covering synthetic bio polymers such as PCL, PLGA, 

PLLA and various hydrogels for scaffold generation, Rokit Invivo is an optimized tool for many of biomedical 

research with its modular system and sterile environment. To be concrete, Invivo users can choose two out of 

three  types  of  nozzles  (extruder,  mechanical  dispenser,  hot  melt  pneumatic  dispenser)  with  additional 

temperature control function to optimize Invivo for their own research purpose. Rokit not only provides medical 

grade  PLGA,  PLLA,  PCL  filament  for  Invivo  extruder,  but  also  gelatin  based  photo-curable  bioink  called 

Invivo@gel  for  printing  wide  range  of  soft  3D  cellular  structures  with  Invivo  dispensers.  Additionally,  Invivo 

provides uncontaminated environment by making the machine closed system with H14 grade HEPA filter for 

external  air  filtration  and  254nm  UV  lamps  for  stage  sterilization.  With  android  OS  touchscreen,  users  can 

upload/download and print the 3D file with wifi network, also monitor printing status with their smart device. As 

a powerful and versatile biomedical research tool, Invivo not only gives you creative research inspiration but 

also actualize it immediately in your lab to attain innovative result for human life.

ROKIT

Modular System of Dual Printing Nozzles

Biopolymer Filaments, Powders, Pallets & Various Hydrogels and Cell laden inks 

Extruder Resolution: 0.2mm~0.4mm / Dispenser Resolution: 0.08mm~0.2mm

Android OS with Wifi Connection Printing

Components with FDA Standard Compliance

Temperature Control System (Premium)

Hot Melt Pneumatic Dispenser (Premium)

Содержание Invivo

Страница 1: ...USER MANUAL ROKIT ...

Страница 2: ... called Invivo gel for printing wide range of soft 3D cellular structures with Invivo dispensers Additionally Invivo provides uncontaminated environment by making the machine closed system with H14 grade HEPA filter for external air filtration and 254nm UV lamps for stage sterilization With android OS touchscreen users can upload download and print the 3D file with wifi network also monitor printi...

Страница 3: ...mm Ø Pneumatic Dispenser 0 1 0 5mm Ø Use caution when turning on the UV lamp Do not use a work bench when a UV lamp is on It may irritate or burn skin and eyes Use a red switch on the upper right side of the machine to turn on off the UV lamp Turn off the UV lamp before opening It requires replacement every 14 months 24hours a day NOTE Keep away from flammable substances It may result in a fire Do...

Страница 4: ...guage setting Identification of Serial number and IP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Dispenser Filament guide Extruder 0 2mm INVIVO PLA Pin 1 8mm Cleaning Pin Allen Wrench Bolt Thickness Gage Syringe Syringe Tip Petri Dish Dongle USB Cable Power Cable Aluminum Case 1ea 1ea 1ea 1ea 1ea 2set 3set 2set 1ea 5ea 3ea 10ea 1ea 1ea 1ea 1ea WHAT S INCLUDED 1 9 5 4 6 7 8 WHAT S IN THE BOX 10 11 12 13...

Страница 5: ...ng material Click the Slicing button on the top to create the G Code file and save it 1 2 3 4 5 6 7 HOW TO USE HOW TO USE SLICER SAVE SLICER SAVE 2 2 3 1 2 1 1 2 3 1 TIP Dispenser2 Right Dispenser Dispenser1 Left Dispenser Dispenser2 Open New Creator K in your computer Click Settings Printer Bio on the top of the menu Open up a 3D modeling file such as stl obj 3ds and amf using File Open Decide th...

Страница 6: ...A bed installation Click New Creator K APP Printer View on the screen To install a bed such as a petri dish adjust the bed mount position using arrow buttons like seen on the screen 1 2 HOW TO USE ...

Страница 7: ...minimize layer of air inside of the syringe After choosing a proper size of a needle tip for the target resolution adjust the height of the dispenser mount to the position of the piston accordingly Move to the New Creator K APP Filament DISPENSER 1 RIGHT on the menu Click 0 1MM 1MM or 10MM on the Distance to move dispenser mounter Adjust the height of the mounter to the piston using UNLOAD or LOAD...

Страница 8: ...ust the distance from a nozzle and a bed After clicking the SET HOME POSITION choose the distance to move among 0 1MM 1MM and 10MM After selecting the moving distance you want click up and down arrows to adjust the distance between an output bed and a nozzle up to the properties such as viscosities of materials The thickness gauge provided will be helpful for this Click the FINISH button to finish...

Страница 9: ...er the extruder nozzle on the SET POSITION menu as much as the height of dispenser Additionally adjust the distance of a bed and a nozzle and then turn the upper screw to change the height of the extruder 1 2 3 HOW TO USE NOTE For dual leveling click the SET POSITION button and then adjust height of the extruder manually to the position of the dispenser nozzle accordingly ...

Страница 10: ...elect the file to print out 1 2 3 HOW TO USE HOW TO USE Using a USB cable to print out on a computer Open the New Creator K app and click CONNECT Insert DEBUG NETWORK IP address 192 168 7 2 and click the Connect button on the right When the computer and INVIVO are connected click the Print after uploading a G code file 1 2 3 CONNECT USB ...

Страница 11: ... and confirm IP address on the WiFi network Open the New Creator K app and then click CONNECT Type the NETWORK IP address 192 168 0 XXX and click the Connect button on the right When the computer and INVIVO are connected click the Print after uploading a G code file 1 2 3 4 5 HOW TO USE ...

Страница 12: ...e Take out the inserted tube pressing the black one touch fitting on the top of the nozzle Remove remains of the material in the nozzle with a sterilized pin 1 2 3 4 5 HOW TO USE HOW TO USE Detaching and Keeping the bio dispenser after use Choose New Creator K APP Filament DISPENSER 1 RIGHT on the screen Click the UNLOAD button Loosen up screws holding a bio dispenser and detach the bio dispenser ...

Страница 13: ...Warmer Put spare bio dispensers in the warmer as seen on the screen Enter the New Creator K APP Printer View Press TEMPERATURE to heat up the bio ink Preheat spare dispensers to use 1 2 3 4 HOW TO USE Temperature ...

Страница 14: ...th process above the internal elements may be overloaded which may cause malfunction Replacement term of INVIVO COOLANT is 1 year TIP The maximum pressure is 9bar 900kpa When you have ooze while your printing Hold VACCUM which is on the Air Dispenser Controller HOW TO USE How to use Air Dispenser Premium Before using the Air Dispenser press SETTING OPTION and press ON on the Dispenser Type Bio INV...

Страница 15: ... power on of Compressor Set preferred pressure by controlling the pressure gauge of Compressor 1 2 3 HOW TO USE TIP Loading of the Air Compressor starts at below 9 8bar and stops when it reaches to 11 3bar Factory setting of compressor is 9 5bar which can be controlled by pressure regulating valve Power Switch Drain Timer Hour Meter Pressure Regulating Valve Regulator Gauge Tank Gauge ...

Страница 16: ...ROKIT Inc 82 02 867 0182 info rokit co kr www rokit co kr www facebook com rokitworld TEL E Mail WEB SNS USER MANUAL ROKIT ...