background image

SM812CH-MV3(T)
SM812CH-MV3

SM385CH-MV3(T)
SM385CH-MV3

SM328CH-MV3(T)
SM328CH-MV3

2013-V01

Digital Indoor Monitor 

Installation and Operation Guide

Содержание SM328CH-MV3

Страница 1: ...SM812CH MV3 T SM812CH MV3 SM385CH MV3 T SM385CH MV3 SM328CH MV3 T SM328CH MV3 2013 V01 Digital Indoor Monitor Installation and Operation Guide ...

Страница 2: ...tment 18 Intercom within the same apartment 18 Call transfer 19 Call the indoor monitor 20 Monitor unlock 21 Home security 23 Information check 26 Call lift 29 Ring 29 SM328 812CH indoor monitor operation guide 30 49 System startup 30 Main menu interface 31 System setting 32 User setting 36 Intercom 38 Call the guard station 38 Call the other apartment 39 Intercom within the same apartment 39 Call...

Страница 3: ...SM385CH MV3 MV3 T Dimension 230x152x21mm 4 screen SM812CH MV3 MV3 T Dimension 222x170x30mm 1 7 screen 1 2 ...

Страница 4: ...Memory space 256M built in Technical parameters Standby current 170 185mA Working current 230 365mA Standby power consumption 2 2 2 8W 8 9 10 14 15 16 17 18 19 20 Indicator light of power Indicator light of network Speaker Indicator light of message MIC Call management centre Unlock door Monitor Talk Volume adjustment Mounting bracket hole Down Up screen ringtone adjustment call lift return key nu...

Страница 5: ...nd power off from the property management center store massage in the indoor monitor The system includes an online upgrade function system upgrade is through the network it makes system maintenance more convenient Installation of indoor monitor Notice Please refer to the steps above fir the installation of SM328 385CH Basic functions 5 6 1 Locate the bracket on the installation place keep it horiz...

Страница 6: ...te Orange Alarm zone 8 sos Alarm zone 7 Gas Alarm zone 6 Fire alarm Alarm zone 5 Alarm zone 4 Alarm zone 3 Alarm zone 2 Alarm zone 1 GND Doorbell Red Black Network cable Call lift Power Black Red Black Red Alarm output Brown Blue Yellow White White Red Black Brown Blue video for second confirmed second confirmed outdoor station Red Black Brown Blue Yellow Green Purple White Orange Alarm zone 8 sos...

Страница 7: ... or the indoor monitor is in the standby mode press any button the screen will show the main menu as picture 1 2 There are video chat monitor home security message check user setting system setting In the main menu press number 6 to choose the 6th option Press the number again to confirm the selection Picture 1 3 the system password interface pops up Enter the correct system password factory defau...

Страница 8: ...r 01 2 digit Room number 01 2 digit Equipment number 0 0 indicates main machine 1 9 indicate the number of slave machines in the blanks Press to delete Press to confirm Press to return MAC address 01 01 00 Address must be unique IP address 192 168 010 100 Address must be unique Subnet Mask 255 255 000 000 If require cross network communication set the subnet mask as 255 255 000 000 For example IP ...

Страница 9: ...e 1 7 4 System password modification picture 1 8 13 14 In the same network the MAC address and IP address can not be the same in any equipment including outdoor station indoor monitor and slave indoor monitors Please according to the actual situation to set the equipments In picture 1 4 press number 3 to choose the second option Press number 3 again to confirm the selection Picture 1 7 will show P...

Страница 10: ...e number again to confirm the selection The chosen icon turns to orange and starts to ring The selection is successful If select No Disturb the indoor monitor ringtone will be turned off and the status icon will be shown in the upper right corner of the main interface When the outdoor station calls the indoor monitor the indoor monitor will not ring In picture 1 10 press number 5 to choose the opt...

Страница 11: ... number For example enter 1002 and press to call the apartment floor 10 room 2 17 18 Press or enter 4 digit guard station equipment number in picture 1 12 such as 0000 and then press to start the call Press or to end the call Users in the same network can call each other In picture 1 12 enter the series number of the apartment building number unit number floor number and room number Then press to ...

Страница 12: ...nsfer this call to other indoor monitors press on the indoor monitor and the call starts to transfer to the rest of the indoor monitors This function is for more than one indoor monitor in one apartment When indoor monitor is called by other equipments indoor monitor will ring Press to pick up the call Press or to end the call Notice When the indoor monitor talk to the outdoor station or the guard...

Страница 13: ... from the outdoor station Press to end the monitor Operation 2 Unlock Notice Notice A The maximum monitor time is 30 seconds After 30 seconds the indoor monitor will hang up automatically In the monitor mode press to open the lock of the outdoor station B If connect to simulated outdoor station press number 0 to monitor the outdoor station When wall outdoor station or unit outdoor station call the...

Страница 14: ...n The chosen icon turns to orange and show defence delay After the 60 seconds default delay time the indoor monitor will show set defence successfully Defence zone delay time default is 60 seconds Alarm delay time default is 60 seconds as picture 1 14 user can change from 0 15 30 and 60 seconds Confirm the number and icon changes to orange The delay time is chosen successfully When the alarm of th...

Страница 15: ...enu interface press number 4 to choose the option Press number 4 again to confirm the selection Picture 1 17 will show the information check There are community information visitor pictures defence record alarm record Community information information sent by the guard stationto the indoormonitor Operation Visitor pictures picture is captured automatically when outdoor station calls indoor monitor...

Страница 16: ...5 Cancel 8 SOS Alarm SOS 2 Information delete In picture 1 18 choose the number of he icon to delete Press and picture 1 20 pops up Enter to delete the message Delete all the information press and hold until the screen shows press to confirm the deletion Then press to confirm the deletion of all the information picture 1 20 Notice The storage is maximum 1000 text and 200 pictures When the storage ...

Страница 17: ...monitor Picture 2 1is the startup screen Startup requires 40 seconds Main interface is as picture 2 2 The screen server will be activated if no operation in 30 seconds After 3 minutes screen saver mode the machine will activate the power saving mode If the touch screen of the indoor monitor does not function well please use the screen emendation process Press for over 3 seconds and the screen emen...

Страница 18: ... to bright colour B Function it includes video intercom monitor home security information check user setting system setting Press the icon to enter the interface C Time it shows the date and time In picture 2 2 main menu interface press system setting icon Picture 2 3 system password will pop up Enter the system password factory default password is 0000 and press to confirm In the picture 2 4 ther...

Страница 19: ...sor will move to the next blank Enter new 4 digit password and confirm the new password Press to confirm all the setting The system shows password changes successfully the blank Press to delete Press to confirm Press to return MAC address 145236 address must be unique IP address 192 168 010 101 address must be unique Subnet mask 255 255 000 000 If require cross network communication the subnet mas...

Страница 20: ... and picture 2 9 will pop up Enter user password factory default password is 1234 Press to confirm In picture 2 10 there are ringtone no interruption and user password setting Operation In picture 2 10 click the ringtone and its icon colour changes to orange and start the ring The selection is completed Select no interruption The indoor monitor will be silent and its icon will turn to bright Durin...

Страница 21: ...4 digit password and confirm the new password Press to confirm all the information The system will show assword changes successfully Operation In picture 2 2 main menu interface click intercom and enter picture 2 12 User can call the guard station intercom with other apartments intercom within the same house call transfer and call indoor monitor Press on the indoor monitor or enter 4 digit guard s...

Страница 22: ...enter floor number room number to call directly For example enter 1002 to call floor 10 room 2 Press to confirm and start calling When there are more than one indoor monitor within the same apartment if outdoor station calls one of the indoor monitor picks up the call and decides to transfer the call to other indoor monitors press the to call the rest of the indoor monitors When user calls all the...

Страница 23: ...menu interface click to enter picture 2 13 monitor view of outdoor station 1 Operation In picture 2 13 press number 1 2 3 4 or to monitor outdoor station 1 to 4 During the monitor mode press to monitor the audio of the outdoor station Press or to end the monitor 1 The maximum monitor time is 30 seconds After 30 seconds indoor monitor will hang up automatically 2 When simulated outdoor station is c...

Страница 24: ...hange from 0 15 30 and 60 seconds Confirm the number and icon changes to orange In picture 2 14 press the mode icon The chosen icon turns to orange and show defence delay After the 60 seconds default delay time the indoor monitor will show set defence successfully When the alarm of the defence zone is triggered picture 2 15 alarm information will pop up The icon turns to orange The guard station a...

Страница 25: ...m and show picture 2 15 In picture 2 2 the main menu interface click to enter Picture 1 17 There are community information visitor pictures defence record alarm record Operation Community information information sent by the guard station to the indoor monitor Visitor pictures picture is captured automatically when outdoor station calls indoor monitor in 6 seconds Defence record details of the defe...

Страница 26: ...heck last and next messages Press to return 1 Information check UP 0 Down Return In picture 2 18 click the information title and press delete Picture 2 20 pops up Click confirm and delete the message Delete all the information press and confirm the deletion of all the information 2 Information delete picture 2 20 Are you sure to delete Notice The storage is maximum 1000 text and 200 pictures When ...

Страница 27: ...ress on the left of the indoor monitor to call the lift Ring 50 Do not close to the strong magnetic fields Avoid water Avoid sun Avoid strong vibration impact and percussion Do not disassemble if you are not professional in this area Avoid using wet towels or volatile chemical to clean indoor monitors Notice ...

Отзывы: