background image

 

LED Indication: 

Power   

        ON/OFF                System activate/ standby. 

 

 

 

        FLASH 

 

   

Panel button or IR remote control disabled by remote PC. 

AUTO SCAN          ON/OFF                 Auto scan function activated/disabled. 
AUTO JUMP          ON/OFF                 Auto jump function activated/disabled. 
1, 2, 3, 4 

        ON   

 

    Currently selected input signal channel. 

FLASH   

 

    No signal input. 

 

Panel Button Function: 

Power:    System activate/ standby. 
AUTO SCAN: Auto scan function activated/disabled. 
AUTO JUMP: Auto jump function activated/disabled. 
DIMMER: LED brightness adjustment. 
1, 2, 3, 4: Currently select input signal channel and disable auto scan function. 

 

Remote Control Operating A,B Mode Switching: 

There are two remote control operating modes: When this device power on, you could 
switch A,B mode by pressing the panel “power” button    and remote control “ *” button 
together. 

 

Mode A operating mode: It come with auto scan & auto jump functions. 
Mode B operating mode: When auto scan & auto jump functions no need to use, which only 
need single button for quick operation on AV switch. 

 

Factory default is set to (Mode A). 

 

IR remote control Mode A Operating: 

  Power symbol 

 

                              System activate/standby. 

                                                                                   

Select next available input and activates auto scan function.

 

 

 

 

 

 

 

                             

Select previous available input and activates auto scan function.

 

                                                                                    Select previous input and disable auto scan function. 

 

 

 

 

 

 

                              Select next input and disable auto scan function. 

1

2

3

4 (5

6

7)   

 

 

         

 

Currently select input and disable auto scan function. 

 

 

 

 

 

                              Auto jump function activated/disabled. 

 

 

 

 

 

                              LED brightness adjustment. 

MENU

ENTER

、*、

、*、

、*、

、*、

(5

6

7)

8

9          Reserved (no function) . 

 

IR remote control Mode B Operating: 

  Power symbol 

 

                                System activate/standby. 

 

 

 

 

 

 

                                Select next input and system activate. 

 

 

 

 

 

 

                                Select previous input and system activate. 

                                                                                      Select previous input and system activate. 

 

 

 

 

 

 

                                Select next input and system activate. 

1

2

3

4 (5

6

7)   

 

 

           

 

Currently select input and system activate. 

 

 

 

 

 

                                LED brightness adjustment. 

MENU

ENTER

、*、

、*、

、*、

、*、

(5

6

7)

8

9

0    Reserved (no function). 

 

Auto Scan Function: 

Under auto scan operation, if the selected input video signal disappears over 0.5 second, it 
would automatically select the previous or next input with video signal. 

 

Auto Jump Function: 

Under auto jump operation, if there is a new video signal input, it will automatically switch 
to a new video signal input. 

 

LED brightness setting: 

LED brightness could be set up as the following 4 levels: 
  1 Minimum Brightness 
  2 Normal Brightness 

3 Maximum Brightness 
4 Brightness auto change 

 

 

Содержание HS04

Страница 1: ...V 480i 576i 480p 576p 720p 1080i and 1080p 60Hz HDCP pass through LED brightness could be adjusted for different environment Built in auto scan switching input function to automatically select the next one with the signal of the input Built in auto jump function to automatically select the new video input Easy to use front panel control of switching or using the included remote control PC Remote c...

Страница 2: ... device could use IR remote control for function setting and control The ID number must be setup before using IR remote control or change new batteries Setup IR remote ID number Press and hold Power Symbol button and press number 0 Installation View HS04 ...

Страница 3: ...xternal Power Consumption 300mA Max 600 mA Max Temperature Operation 0 to 55 Storage 20 TO 85 Humidity up to 95 Dimensions mm 253 x 138 5 x 40 Weight g 770 775 ITEM RC01 PC RS 232 DB9 Connector Female Console 4 PIN Female Header Distance 15M max Baud Rate 115200 bps max Power Source DC From Terminal 5V Power Consumption 50 mA max Temperature Operation 0 to 55 Storage 20 TO 85 Humidity up to 95 Dim...

Страница 4: ...ate standby Select next available input and activates auto scan function Select previous available input and activates auto scan function Select previous input and disable auto scan function Select next input and disable auto scan function 1 2 3 4 5 6 7 Currently select input and disable auto scan function 0 Auto jump function activated disabled LED brightness adjustment MENU ENTER 5 6 7 8 9 Reser...

Страница 5: ...can SCAN y Auto scan function activated disabled JUMP y Auto jump function activated disabled ACTIVATE System activate STANDBY System standby MODE x Select operation mode A B IR y IR remote button lock unlock KEY y Panel button lock unlock LED n LED brightness adjustment SAVE Save setting LOAD Load setting KEYPAD Keypad mode operation SIGNAL Display input signal status STATUS Display setting VERSI...

Страница 6: ...on MODE A COMMAND DESCRIPTION System activate standby Q Command mode operation S Display setting and input signal status Show all commands MODE B COMMAND DESCRIPTION 1 2 3 4 Currently select input and system activate Select previous input and system activate Select next input and system activate L Select previous input and system activate R Select next input and system activate System activate sta...

Отзывы: