TECHNICAL FEATURES
Gas
Category
Gas
Minimum
Power
(consumption)
Medium Power
(consumption)
Maximum
Power
(consumption)
Usage
Pressure
G30
I3+
1.6Kw 100g/h
2.8Kw 200g/h
4.2Kw 300g/h
28-30 mbar
This Appliance is designed to operate on LPG at a nominal pressure of 30 mbar. For a regular combustion of the gas
an amount of air equal to 8.4 m3 /h is required.
Table I
COMMISSION REGULATION (EU) 2015/1188 (28 April 2015)
Model identifier
Primavera
Indirect heating function: (yes /
no)
NO
Direct thermal power [
kW]
4.2
Indirect thermal power [
kW]
0
Fuel
Emissions due
to
environment
heating
NOx
(1)
Select the type of fuel
[gaseous / liquid]
[to specify]
[
mg /
kWh
input
]
(
GCV
)
G30
gaseous
NA
(2)
Data
Symbol
Value
Unit
Data
Symbol
Value
Unit
Thermal power
Useful efficiency (NCV)
Nominal thermal
power
P
nom
4.2
kW
Useful efficiency at nominal heat
output
η
th, nom
NA
(2)
%
Minimum heat
output (indicative)
P
min
1,
6
kW
Useful efficiency at minimum
heat output (indicative)
η
th, min
NA
(2)
%
Type of thermal power / control of the ambient temperature
Two or more manual steps without control of room temperature
YES
Power required for the pilot flame
P
pilot
0.160
kW
Contacts
Bartolini Srl Via
G.
di
Vittorio,
19 - 06038 Spello (PG)
(1)
NO
x
= nitrogen oxides
(2)
NA =
Not Applicable
(no reference standard applicable to the product, which provides for measurement of this
parameter)
Содержание PRIMAVERA
Страница 1: ...PRIMAVERA T This product is not suitable for primary heating functions...
Страница 4: ...15 Kg BEBAI UNI CIG 7140 G 400mm H UNI CIG 7131 30mbar UNI CIG 7141 O 1 2 10 3 20 4 5 20 6 ODS CO2...
Страница 5: ...5 2002 96...
Страница 10: ...www vassilias gr 8 111 45 210 8543260 Fax 210 8543271...