Problem
Possible Causes
Solution
● Check whether there is ● Make sure there is no curtain,
any obstacle around the
unit.
shutter or furniture that blocks
blocked.
● Make sure all doors and
windows and other opening to
the outside have been
closed.
Bad dehumidifying ● Doors and windows are
performance
left open.
● Warm temperature is good for
● Room temperature is too ature will reduce unit's working
low.
effect. This unit should be wor-
king in a place where temper-
ature is above 5°C.
12
Bucket full indicator
is lit up.
Unit can function
● Bucket is not properly
placed.
● Water is full in the bucket.
● Bucket has been removed.
● Empty the bucket and replace
it.
● If you want the air drier,
press - button to lower the
for unit to dehumidify
continuously.
normally but it can ● Humidity is set too high.
not start up.
Unit's Malfunction Codes Units Condition
Dispay Code “E1” --- Humidity Sensor is damaged
Display Code “E2” --- Temperature Sensor is damaged
Defrost procedure
Please note if the ROOM temperature is less than 24
℃
, the unit will start defrost function!
≥24°C: n
o defrost
18-
23°C 2hours dehumidify then 5minute defrost, cycle;
12-
18°C: 25minute dehumidify then 5minute defrost, cycle;
5-
12°C: 20minute dehumidify then 5minute defrost, cycle; 5
-
12°C
≤5°C: unit protection, compressor of, fan of. All operation mode
cannot be activated except air