7.2
Maintenance Interval
The regular maintenance work is described in the following:
Activity
Interval
Lubricate conical lubricating nipple.
Approx. every 20 hrs.
depending on conditions of use and
use of coolant after 8 hrs.
or at the latest after 10,000 clamping
cycles.
Lubricate jaw guide.
With each jaw replacement or at the
latest after 2,500 clamping cycles.
Check clamping force with clamping
force measurement system F-Senso
Chuck.
After 30,000 clamping cycles or after
3 months depending on the conditions
of use.
Visually inspect wear parts.
Weekly
Check tightness of screw connec-
tions.
Weekly
Visually inspect jaw screws.
Weekly
Replace jaw screws.
Annually
Inspection of the power chuck.
Annually
7.3
Maintenance Work
CAUTION
Skin irritations due to contact with lubricants.
The constituents of the lubricant may cause irritations in the event of
contact with the skin.
Ø
When handling the
power chuck
, wear safety goggles, long
work clothes and gloves.
Ø
Avoid skin contact with lubricants.