Table 2. Charging state transition condition
No.
State transition
Condition
①
SUSPEND -> CHARGE
UVLO, TSD not detect
and VIN > V
BAT
+0.3 V
and V
BAT
OVP not detect
and Temp Error not detect
Continue to satisfy the condition for 25 ms
②
CHARGE -> TOP_OFF
Charge current < I
TERM
Continue to satisfy the condition for 25 ms
③
TOP_OFF -> CHARGE
Charge current > I
TERM
Continue to satisfy the condition for 25 ms
④
TOP_OFF -> DONE
Continue to satisfy the
③
condition for 15 s
⑤
CHARGE or TOP_OFF or
TEMP_ERROR_1 or
TEMP_ERROR_2
-> BATTERY ERROR
V
BAT
OVP detect
or 10 hours safety timer expired
⑥
DONE -> CHARGE
V
BAT
< Re-charge voltage
Continue to satisfy the condition for 25 ms
⑦
CHARGE -> TEMP_ERROR_1 or
TOP_OFF -> TEMP_ERROR_2
Temp Error detect
Continue to satisfy the condition for 25 ms
⑧
TEMP_ERROR_1 -> CHARGE or
TEMP_ERROR_2 -> TOP_OFF
Temp Error not detect
Continue to satisfy the condition for 25 ms
⑨
ALL State -> SUSPEND
UVLO, TSD detect
or VIN < V
BAT
+0.3 V
Table 3. Safety timer and Internal control settings for each state of LEDCNT
State
Battery charge
10 hours safety timer
LEDCNT
SUSPEND
Stop
Stop and reset
Hi-Z
CHARGE
Charge
Count
Low
TOP_OFF
Charge
Count
Low
DONE
Stop
Stop and reset
Hi-Z
BATTERY_ERROR
Stop
Stop and reset
Hi-Z
TEMP_ERROR_1
Stop
Count
Hi-Z
TEMP_ERROR_2
Stop
Count
Hi-Z