2/8
●
Absolute Maximum Rating (Ta=25
℃
)
Parameter Symbol Limits
Unit
Power Supply Voltage
VCC
-0.3 ~ +10
V
Output Voltage
Po
-0.3 ~ +10
V
Power Dissipation
*1
*2
Pd
540
mW
Operating Temperature
Topr
-40 ~ +75
℃
Ambient Storage Temperature
Tstg
-55 ~ +125
℃
*
1 When a ROHM standard circuit board (70mm×70mm×1.6mm glass epoxy board) is mounted.
*
2 When used at temperatures higher than Ta=25
℃
, the power is reduced by 5.4mW/
℃
●
Electrical Characteristics (Unless specified otherwise, Ta=-25
℃
~+105
℃
)
Parameter Symbol
Min.
Typ.
Max.
Unit
Conditions
Detection Voltage
VS
VS (T)×0.99 VS (T) VS (T)×1.01
V
RL=470k
Ω
,VDD=H
→
L
Detection Voltage
Temperature Coefficient
VS/
∆
T
-
±0.01
-
%/
℃
RL=4.7k
Ω
,Ta=-20
~
+75
℃
(Designed Guarantee)
Hysteresis Voltage
∆
VS
30 50
100 mV
RL=4.7k
Ω
,VCC=L
→
H
→
L
“H” Transmission Delay Time
*1
TPLH
-
20 50 µs
CL=100p
F
,RL=4.7k
Ω
“L” Transmission Delay Time
*2
TPHL
-
60 120
µs
CL=100p
F
,RL=4.7k
Ω
“L” Output Voltage
VOL
-
0.1 0.4 V
VCC=VSMin.-0.05V,RL=4.7k
Ω
Circuit Current at ON
ICC1
-
1.5 3.0 µA
VCC=VSMin.-0.05V,RL=
∞
Circuit Current at OFF
ICC2
-
1.6 3.2 µA
VCC=VSTyp./0.85V,RL=
∞
Operating Voltage Range
VOPL
-
0.65
0.85 V
RL=4.7k
Ω
,VOL
≧
0.4V
“Low” Output Current
IOL
3.0
15.0
-
mA
Vo=0.4V,VCC=VsMin.-0.05V
Note: VS(T) = Setting Detection Voltage Value (1.9V
~
4.6V
,
0.1V step)
*1 TPLH: VCC =
(
VS Typ.-0.4V
)
→
(
VS Typ.+0.4V
)
*2 TPHL: VCC =
(
VS Typ.+0.4V
)
→
(
VS Typ.-0.4V
)
Designed Guarantee. (Outgoing inspection is not done an all products.)
●
Block Diagrams
PIN No.
Symbol
Function
1 N.C.
Unconnected
Terminal
2 SUB
Substrate*
3 GND
GND
4 VOUT
Reset
Output
5
VCC
Power Supply Voltage
*Substrate Pin should be connected with GND
TOP VIEW
SSOP5
Fig.1
Vref
V
OUT
V
CC
GND
5
4
3
electronic components distributor