Command Reference
R&S
®
ZNB/ZNBT
1178
User Manual 1173.9163.02 ─ 38
TRIGger<Ch>[:SEQuence]:MULTiple:SOURce
............................................................... 1180
................................................................................ 1180
..............................................................................1181
TRIGger<Ch>[:SEQuence]:HOLDoff
<DelayTime>
Sets a delay time between the trigger event and the start of the measurement ("Trigger
Delay").
Suffix:
<Ch>
.
Channel number.
Parameters:
<DelayTime>
Delay time.
Range:
0 s to 13680 s
Increment: 10 ms
*RST:
0 s
Default unit: s
Example:
TRIG:SOUR MAN
Activate external trigger source.
TRIG:HOLD UP
Set a delay time of 10 ms.
Manual operation:
See
TRIGger<Ch>[:SEQuence]:LINK
<MeasSequence>
Selects the triggered measurement sequence. The identifier for the sequence is a
string variable.
Suffix:
<Ch>
.
Channel number
Parameters:
<MeasSequence>
Triggered measurement sequence, string variable.
'SWEep'
–
trigger event starts an entire sweep.
'SEGMent'
–
trigger event starts a sweep segment, if segmented
frequency sweep is active (see example below). If another
sweep type is active, the trigger event starts an entire sweep.
'POINt'
–
trigger event starts measurement at the next sweep
point.
'PPOint'
–
trigger event starts the next partial measurement at
the current or at the next sweep point.
*RST:
'SWEep'
SCPI Command Reference