Function Description
R&S
®
TS-PSM2
13
User Manual 1178.2773.02 ─ 01
consists of integrating project-specific additions via the side and system connector X50
(for example passive loads, terminating resistors, voltage distributors, etc.).
5.1.4 Compactness
The layout of the R&S TS-PSM2 (one slot) with 112 relays offers maximum space sav-
ings. Extremely high-powered and compact measurement and load systems can be set
up with as many as 12 modules in the R&S CompactTSVP and 16 modules in R&S
PowerTSVP. These measurement and load systems can be integrated directly into
manufacturing cells, which makes them very cost-efficient.
5.1.5 Noise Immunity
Optimum response to electrical interference or rises in temperature is achieved by the
controller on the serial differential CAN bus (Controller Area Network).
5.1.6 Sample applications
5.1.6.1
Simple switching function - normally open, 1-pin.
The relay switches the channel on and off; the shunt resistor is not used.
CHx_HI2...4
Figure 5-2: The relay switches the channel on and off; the shunt resistor is not used.
5.1.6.2
Simple switching function - changeover contact, 1- pin.
The relay switches the channel; the shunt resistor is not used.
CHx_HI1
CHx_LO1
Figure 5-3: Simple switching function - changeover contact, 1-pin.
R&S TS-PSM2