![Rohde & Schwarz SMM100A Скачать руководство пользователя страница 836](http://html.mh-extra.com/html/rohde-and-schwarz/smm100a/smm100a_user-manual_1477939836.webp)
Remote control commands
R&S
®
SMM100A
836
User Manual 1179.1341.02 ─ 05
Manual operation:
See
Trigger commands
[:SOURce<hw>]:BB:ARBitrary[:TRIGger]:SEQuence
......................................................... 836
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SOURce
..............................................................836
[:SOURce<hw>]:BB:ARBitrary:TRIGger:RMODe?
............................................................. 837
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SLENgth
..............................................................837
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SLUNit
................................................................ 837
[:SOURce<hw>]:BB:ARBitrary:TRIGger:ARM:EXECute
..................................................... 837
[:SOURce<hw>]:BB:ARBitrary:TRIGger:EXECute
............................................................. 838
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal]:SYNChronize:OUTPut
...........................838
[:SOURce<hw>]:BB:ARBitrary:TRIGger:PTIMe?
............................................................... 838
[:SOURce<hw>]:BB:ARBitrary:TRIGger:DELay:UNIT
........................................................ 838
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal]:DELay
................................................. 839
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal]:TDELay
............................................... 839
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal]:RDELay?
............................................. 839
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal]:INHibit
................................................. 840
[:SOURce<hw>]:BB:ARBitrary[:TRIGger]:SEQuence
<Sequence>
The command selects the trigger mode.
Parameters:
<Sequence>
AUTO | RETRigger | AAUTo | ARETrigger | SINGle
*RST:
AUTO
Example:
See
Example "Managing waveform files"
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SOURce
<Source>
Selects the trigger signal source and determines the way the triggering is executed.
Provided are:
●
Internal triggering by a command (
INTernal
)
●
External trigger signal via one of the local or global connectors
–
EGT1|EGT2
: External global trigger
–
EGC1|EGC2
: External global clock
●
In primary-secondary instrument mode, the external baseband synchronization sig-
nal (
BBSY
)
●
OBASeband|BEXTernal|EXTernal
: Setting only
Provided only for backward compatibility with other Rohde
&
Schwarz signal gener-
ators.
The R&S
SMM100A accepts these values and maps them automatically as follows:
EXTernal = EGT1
,
BEXTernal = EGT2
,
OBASeband = INTA
SOURce subsystem