13.16.4.1
SOURce:BB subsystem general commands
The following section describes the commands for setting the frequency shift and the
phase offset for the signal at the output of the "Baseband" and "BB Input" blocks.
The following commands are available:
.......................................................................................768
..........................................................................................768
.......................................................................................768
..........................................................................................768
............................................................................................ 769
.........................................................................................769
.................................................................................769
.........................................................................................769
.................................................................................. 770
[:SOURce<hw>]:BBIN:FOFFset
<FOffset>
[:SOURce<hw>]:BB:FOFFset
<FOffset>
Sets a frequency offset for the internal/external baseband signal. The offset affects the
generated baseband signal.
Parameters:
<FOffset>
float
Range:
depends on the installed options
Increment: 0.01
*RST:
0
Default unit: Hz
Example:
SOURce1:BB:FOFFset 2MHZ
Manual operation:
See
[:SOURce<hw>]:BBIN:POFFset
<POffset>
Sets the relative phase offset for the external baseband signal.
Parameters:
<POffset>
float
Range:
-999.99 to 999.99
Increment: 0.01
*RST:
0
Default unit: DEG
Example:
SOURce1:BBIN:POFFset 0.5
Manual operation:
See
[:SOURce<hw>]:BB:POFFset
<POffset>
Sets the relative phase offset for the selected baseband signal.