Remote control commands
R&S
®
SMM100A
754
User Manual 1179.1341.02 ─ 05
Example: Using an external signal source
Alternatively configure the frequency modulation settings with an external modulation
signal.
// Reset the instrument to start from a defined state
*RST
// Set RF frequency and amplitude
SOURce1:FREQuency:CW 6000000000
SOURce1:POWer:LEVel:IMMediate:AMPLitude -25
// Configure the frequency modulation settings and switch FM on
SOURce1:FM1:SOURce EXT1
SOURce1:FM1:DEViation 5000
// Query the input sensitivity at the external modulation input
:SOURCe1:FM1:SENSitivity?
// Response: 1000
// since the voltage value for full modulation is 1V,
// the resulting sensitivity is precisely 5000 Hz/V.
// Switch on FM and RF signal output
SOURce1:FM1:STATe 1
OUTPut1:STATe 1
The following commands are available:
......................................................................................754
[:SOURce<hw>]:FM<ch>[:DEViation]
............................................................................... 755
.................................................................................. 755
[:SOURce<hw>]:FM:DEViation:MODE
............................................................................. 756
[:SOURce<hw>]:FM:DEViation:SUM
................................................................................756
..............................................................................................756
.............................................................................................757
.....................................................................................757
[:SOURce<hw>]:FM<ch>:STATe
<State>
Activates frequency modulation.
Suffix:
FM<ch>
.
1..2
determines the modulation signal channel.
Parameters:
<State>
1 | ON | 0 | OFF
*RST:
0
Example:
See
Example "Creating a frequency modulated RF signal"
Manual operation:
See
SOURce subsystem