Configuring the internal baseband source
R&S
®
SMM100A
122
User Manual 1179.1341.02 ─ 05
Remote command:
Load User Mapping
Accesses the "Select List File User Mapping" dialog to select the mapping table (see
on page 103). The dialog provides all standard file management func-
tions.
Remote command:
[:SOURce<hw>]:BB:DM:MLISt:SELect
[:SOURce<hw>]:BB:DM:MLISt:CATalog?
[:SOURce<hw>]:BB:DM:MLISt:DELete
ASK Depth
Sets the modulation depth
m
for ASK modulation.
m = (Amplitude
max
-Amplitude
min
) / (Amplitude
max
+Amplitude
min
)
Remote command:
FSK Deviation
Sets the frequency deviation for FSK modulation. The range of values depends on the
selected
(see data sheet).
Whenever "MSK" is selected, the deviation corresponds to 1/4 of the symbol rate and
cannot be changed.
Remote command:
[:SOURce<hw>]:BB:DM:FSK:DEViation
Angle Alpha
For AQPSK modulation, sets the angle alpha between the point (0,0) and the I axis.
Remote command:
[:SOURce<hw>]:BB:DM:AQPSk:ANGLe
FSK Type
For "Variable FSK", selects the FSK modulation type.
Available are 4FSK, 8FSK and 16FSK.
Generating custom digital modulated signals