Remote Control Commands
R&S
®
SMBV100B
797
User Manual 1178.4460.02 ─ 03
SOURce1:AWGN:DISP:MODE RFA
SOURce1:AWGN:POWer:MODE CN
SOURce1:AWGN:POWer:RMODe CARRier
SOURce1:AWGN:BRATe?
// Response: 100000
SOURce1:AWGN:CNRatio 12.7
SOURce1:AWGN:ENRatio?
// Response: 23.0342375548695
SOURce1:AWGN:POWer:CARRier?
// Response: -76
// the Level display indicates the PEP of the carrier
// Querry the resulting noise power, in the system and total bandwidht
SOURce1:AWGN:POWer:NOISe?
// Response: -88.7
SOURce1:AWGN:POWer:NOISe:TOTal?
// Response: -88.7
// Querry the noise power and PEP
SOURce1:AWGN:POWer:SUM?
// Response: -75.7728170942726
SOURce1:AWGN:POWer:SUM:PEP?
// Response: -76
........................................................................................797
....................................................................................... 798
......................................................................................798
[:SOURce<hw>]:AWGN:BWIDth:RATio
............................................................................ 798
[:SOURce<hw>]:AWGN:BWIDth:NOISe?
..........................................................................799
...............................................................................799
............................................................................799
[:SOURce<hw>]:AWGN:POWer:RMODe
..........................................................................799
....................................................................................... 800
.....................................................................................800
..................................................................................... 800
[:SOURce<hw>]:AWGN:POWer:CARRier
.........................................................................800
[:SOURce<hw>]:AWGN:POWer:NOISe
............................................................................801
[:SOURce<hw>]:AWGN:POWer:NOISe:TOTal?
.................................................................801
.............................................................................801
[:SOURce<hw>]:AWGN:POWer:SUM:PEP?
..................................................................... 802
[:SOURce<hw>]:AWGN:FREQuency:TARGet
................................................................... 802
[:SOURce<hw>]:AWGN:FREQuency:RESult?
...................................................................802
[:SOURce<hw>]:AWGN:STATe
<State>
Activates or deactivates the AWGN generator.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
See
Example "Generating a pure noise signal"
SOURce Subsystem