Example:
Setting in the second slave instrument Slave#2:
:SOURce:INPut:DELay:SPOSition 2
:SOURce:INPut:DELay:CLENgth1 1
:SOURce:INPut:DELay:CLENgth2 0.5
:SOURce:INPut:DELay:ADCState ON
Manual operation:
See
"Automatic Delay Compensation"
7.16.9 SOURce:IQ Subsystem
This subsystem contains the commands for checking the I/Q modulation.
......................................................................................746
[:SOURce<hw>]:IQ:IMPairment:IQRatio[:MAGNitude]
........................................................746
[:SOURce<hw>]:IQ:IMPairment:LEAKage:I
.......................................................................747
[:SOURce<hw>]:IQ:IMPairment:LEAKage:Q
..................................................................... 747
[:SOURce<hw>]:IQ:IMPairment:QUADrature[:ANGLe]
....................................................... 747
[:SOURce<hw>]:IQ:IMPairment[:STATe]
.......................................................................... 748
...........................................................................................748
..............................................................................................748
................................................................................. 748
..........................................................................................749
[:SOURce<hw>]:IQ:CREStfactor
<CrestFactor>
Sets the crest factor of the external analog signal.
Parameters:
<CrestFactor>
float
Range:
0 to 35
Increment: 0.01
*RST:
0
Default unit: dB
Example:
IQ:CRES 10
specifies a crest factor of 10 dB for the external analog signal.
Manual operation:
See
[:SOURce<hw>]:IQ:IMPairment:IQRatio[:MAGNitude]
<Magnitude>
This command sets the ratio of I modulation to Q modulation (amplification “imbal-
ance”).
Parameters:
<Magnitude>
float
Range:
-1.0dB to +1.0dB
Increment: 0.005dB
*RST:
0
Default unit: 0dB