Remote Control Commands
R&S
®
SMBV100A
734
Operating Manual 1176.8016.02 ─ 17
Parameters:
<Source>
INTernal | EXTernal | INT,EXT
INT
Uses the internally generated signal for modulation. To configure
the frequency, use the commands of the
EXT
Uses an externally applied modulation signal.
The external signal is input at the EXT MOD connector.
INT,EXT
Uses both, the internal and external modulation signals.
*RST:
INT
Example:
FM:SOUR INT
selects the internal modulation source.
Manual operation:
See
[:SOURce<hw>]:FM:STATe
<State>
Activates frequency modulation.
Note:
Activation of FM deactivates phase modulation (PM).
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
FM:STAT ON
Activates FM modulation.
Manual operation:
See
7.16.7 SOURce:FREQuency Subsystem
This subsystem contains the commands used to define the frequency settings for the
RF sources and sweeps.
[:SOURce<hw>]:FREQuency:CENTer
..............................................................................735
[:SOURce<hw>]:FREQuency:LOSCillator:MODE
.............................................................. 736
[:SOURce<hw>]:FREQuency:LOSCillator:OUTPut:STATe
................................................. 736
[:SOURce<hw>]:FREQuency[:CW|FIXed]
.........................................................................736
[:SOURce<hw>]:FREQuency[:CW|FIXed]:RCL
................................................................. 737
[:SOURce<hw>]:FREQuency:MANual
..............................................................................737
................................................................................738
[:SOURce<hw>]:FREQuency:MULTiplier
..........................................................................739
[:SOURce<hw>]:FREQuency:OFFSet
.............................................................................. 739
.................................................................................739
................................................................................740
SOURce Subsystem
Содержание SMBV100A
Страница 1: ...R S SMBV100A Vector Signal Generator Operating Manual Operating Manual 1176 8016 02 17 ÚÞ 2 ...
Страница 31: ...Contents R S SMBV100A 16 Operating Manual 1176 8016 02 17 ...
Страница 129: ...Manual Operation R S SMBV100A 114 Operating Manual 1176 8016 02 17 Legend of Front Panel Controls ...