![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 755](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735755.webp)
Remote Control Commands
R&S
®
SMBV100A
740
Operating Manual 1176.8016.02 ─ 17
Parameters:
<Span>
float
Range:
full frequency range
Increment: see the data sheet: RF characteristics > Resolution
of setting
*RST:
400E6
Example:
FREQ:CENT 400 MHz
sets the center frequency of the frequency sweep to 400 MHz.
FREQ:SPAN 200 MHz
sets a span of 200 MHz. This sets the sweep range to 300 MHz
to 500 MHz.
Manual operation:
See
[:SOURce<hw>]:FREQuency:STARt
<Start>
Sets the start frequency for the RF sweep.
This parameter relates to the center frequency and span. If you change the frequency,
these parameters change accordingly.
f
STARt
> f
STOP
is permitted.
f
STARt
= (f
CENTer
- f
SPAN
/2).
Note:
A defined offset and the multiplier factor affect the sweep range and therefore all
correlated parameters. The set frequencies are only absolute values, if the offset = 0
and the multiplication factor = 1. The multiplier multiplies the frequencies accordingly,
and the offset ≠ 0 shifts the frequencies corresponding to the set value.
f
STARt
* f
MULTiplier
+ f
OFFset
... f
STOP
* f
MULTiplier
+ f
OFFset
Parameters:
<Start>
float
Range:
full frequency range
Increment: see the data sheet: RF characteristics > Resolution
of setting
*RST:
100 MHz
Example:
FREQ:STARt 1 MHz
sets the start frequency for the frequency sweep to 1 MHz.
FREQ:STOP 2 GHz
sets the stop frequency for the frequency sweep to 2 GHz.
Manual operation:
See
" Start Freq - Frequency Sweep "
[:SOURce<hw>]:FREQuency:STOP
<Stop>
Sets the stop frequency for the RF sweep.
This parameter is related to the center frequency and span. If you change the fre-
quency, these parameters change accordingly.
SOURce Subsystem