Figure 5-15: I offset (left) and Q offset (right) in the I/Q constellation diagram
5.7.1.3
Quadrature Offset
Changes the phase angle between the I and the Q vectors from the ideal 90 degrees,
while the amplitudes are maintained. A positive quadrature offset results in a phase
angle greater than 90 degrees. The effect of a positive quadrature offset in the I/Q con-
stellation diagram is shown on
Figure 5-16: Positive quadrature offset in the I/Q constellation diagram
5.7.1.4
Impairment Settings Menu
To access the "Impairment Settings" menu for setting the digital I/Q impairments,
select "AWGN/IMP > Configure > I/Q Impairements" or use the MENU key under
"AWGN/IMP".
Impairment of Digital I/Q Signal and Noise Generator - AWGN/IMP Block