Spectrum Analysis
R&S
®
Scope Rider RTH
141
User Manual 1326.1578.02 ─ 12
Save, Save As
Save the harmonic results. The functions are available if the instrument is in "Harmon-
ics" mode.
"Save"
Saves the file in the defined "Harmonic Directory" using the autonam-
ing pattern.
"Save As"
Opens a file explorer where you can select the directory and enter the
filename.
Remote command:
Harmonic Directory
Defines the directory where the harmonic results files are stored. If a USB flash drive is
connected, the instrument stores the data to this external device by default.
Remote command:
Filename Base
Defines the first part of the filename. The complete filename pattern is:
<filename base>_<date>_<time>.csv
.
Remote command:
6.3.6
File Formats for Harmonic Results and Limits
6.3.6.1
Limit File Format
The limit file defines which harmonics are of interest for analysis, and optionally, the
limits against which each harmonic is to be tested. If a user-defined limit file is loaded
for harmonics measurement, only the results for the specified harmonics are calcula-
ted, displayed, and exported. A limit check is performed only for those harmonics for
which a limit value is defined.
Sample file
A sample limit file is provided on the instrument:
C:\Users\<user_name>\Rohde-Schwarz\RTH\Harmonic\LimitExample.csv
The file format is a comma-separated list
(.csv)
. At least the following contents must
be included:
Header:
<Device>,Version,<file_version>
Harmonics,Limit[%]
Values:
Harmonics Measurement (Option R&S
RTH-K34)