Remote Control
R&S
®
RTM20xx
434
User Manual 1317.4726.02 ─ 01
is set to
IDENtifier
,
IDData
or
IDERror
.
Parameters:
<Identifier>
String containing binary pattern. Characters 0, 1, and X are
allowed. Enter the 6 bit identifier without parity bits, not the pro-
tected identifier.
SEARch:PROTocol:LIN:DLENgth
<DataLength>
Defines the length of the data pattern - the number of bytes in the pattern.
is set to
IDData
.
Parameters:
<DataLength>
Range:
1 to 8
Increment: 1
*RST:
1
Default unit: Byte
SEARch:PROTocol:LIN:DCONdition
<DataCondition>
Sets the comparison condition for data: If the pattern contains at least one X (don't care),
you can trigger on values equal or not equal to the specified value. If the pattern contains
only 0 and 1, you can also trigger on a range greater than or lower than the specified
value.
is set to
IDData
.
Parameters:
<DataCondition>
EQUal | NEQual | GTHan | LTHan
*RST:
EQU
SEARch:PROTocol:LIN:DATA
<Data>
Defines the data pattern. The pattern length is defined with
.
is set to
IDData
.
Parameters:
<Data>
String containing binary pattern with max. 64 bit. Characters 0, 1,
and X are allowed. Make sure to enter complete bytes.
15.2.14 Mixed Signal Option (MSO, R&S
RTM-B1)