Remote Control
R&S
®
RTM20xx
307
User Manual 1317.4726.02 ─ 01
Parameters:
<Time1>
Center value, maximum value or minimum value depending on the
defined range type.
Range:
2,00E-008 to 6.87194685440
Increment: Depends on the <Time1> value
*RST:
2,00E-008
15.2.5.4
Video/TV Trigger
................................................................................................307
TRIGger:A:TV:STANdard
<Standard>
Selects the color television standard.
Parameters:
<Standard>
PAL | NTSC | SECam | PALM | I576 | P720 | P1080 | I1080
PALM = PAL-M
I576 = SDTV 576i (PAL and SECAM)
P720 | P1080 = HDTV 720/1080p (progressive scanning)
I1080 = HDTV 1080i (interlaced scanning)
*RST:
PAL
TRIGger:A:TV:POLarity
<Polarity>
Selects the polarity of the signal. Note that the sync pulse has the opposite polarity. The
edges of the sync pulses are used for triggering,
See also:
Parameters:
<Polarity>
POSitive | NEGative
POSitive
If the video modulation is positive, the sync pulses are negative.
NEGative
If the modulation is negative, sync pulses are positive.
*RST:
NEGative
TRIGger:A:TV:FIELd
<Field>
Sets the trigger on the beginning of the video signal fields, or on the beginning of video
signal lines.
Command Reference