Remote Control
R&S
®
RTM20xx
281
User Manual 1317.4726.02 ─ 01
Example:
chapter 15.3.1.2, "Reading Waveform Data in Unsigned Inte-
Usage:
Query only
CHANnel<m>:DATA:YRESolution?
CHANnel<m>:DATA:ENVelope:YRESolution?
CALCulate:MATH<m>:DATA:YRESolution?
REFCurve<m>:DATA:YRESolution?
Return the vertical bit resolution of the indicated waveform.
The commands are relevant for data conversion if binary data format is defined
).
Return values:
<Yresolution>
For default waveforms, the resolution is 8 bit.
If high resolution, average or filter are set for the waveform, the
resolution is 16 bit.
Example:
chapter 15.3.1.2, "Reading Waveform Data in Unsigned Inte-
Usage:
Query only
15.2.4 Acquisition and Setup
Starting and Stopping Acquisition
.........................................................................281
15.2.4.1
Starting and Stopping Acquisition
................................................................................................282
RUN
Starts the continuous acquisition.
Usage:
Event