Product Description

The R&S

 

RT-ZF5 test fixture is a multipurpose fixture to probe or tap Ethernet sig-

nals up to the 10GBASE-T standard.

The fixture can be used to separate the directions of a full duplex connection for
decoding applications like R&S

 

RTO/R&S

 

RTP-K57 (100BASE-T1).

The R&S

 

RT-ZF5 can also be used for compliance testing of energy-efficient

Ethernet (100BASE-TX and 1000BASE-T). For compliance testing, it is used in
combination with:

R&S

 

RTO/R&S

 

RTP oscilloscope

EEE: R&S RTO-K86 (1333.1992.02), R&S RTP-K86 (1337.8833.02): requires
R&S

 

RTO/R&S

 

RTP-K22

R&S

 

ScopeSuite software

For data, see the "R&S

 

RT-ZFxx Oscilloscope Test Fixtures - Specifications" at

www.rohde-schwarz.com/brochure-datasheet/rto

.

2.1

 

Deliveries

The R&S

 

RT-ZF5 delivery package contains the following items:

R&S

 

RT-ZF5 test board

Manual

2.2

 

Board Description

The R&S

 

RT-ZF5 Ethernet probing fixture has three labeled sections, which are

designed for specific test cases. You can cut the board at the section limits and
use each section as a separate board.

"Directional Probe" section

Separates the signals on a (differential) full duplex Ethernet connection (like
1000BASE-T or 100BASE-T1) into a forward signal and a backward signal. The

Board Description

Содержание RT-ZF5

Страница 1: ...R S RT ZF5 Ethernet Probing Fixture Manual Manual Version 02 1333231802 QGB2 ...

Страница 2: ... 49 89 41 29 12 164 Email info rohde schwarz com Internet www rohde schwarz com Subject to change Data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are trademarks of the owners Throughout this manual products from Rohde Schwarz are indicated without the symbol e g R S RT ZF5 is indicated as R S RT ZF5 ...

Страница 3: ...equipment is operated by trained personnel Operating site Only use the product indoors and keep it dry The product has no casing and is sensitive to moisture and humidity The product is suitable for pollution degree 2 environments where nonconductive contamination can occur For more information on environmental conditions such as ambient temperature see the specifications Installation Make sure to...

Страница 4: ... S RTO K86 1333 1992 02 R S RTP K86 1337 8833 02 requires R S RTO R S RTP K22 R S ScopeSuite software For data see the R S RT ZFxx Oscilloscope Test Fixtures Specifications at www rohde schwarz com brochure datasheet rto 2 1 Deliveries The R S RT ZF5 delivery package contains the following items R S RT ZF5 test board Manual 2 2 Board Description The R S RT ZF5 Ethernet probing fixture has three la...

Страница 5: ...ction Used to tap the connection between two Ethernet devices It offers pins for differ ential and single ended probes to ground probe connections R S RT ZF5 Ethernet Probing Fixture Directional Probe Load and Probe DUT and Link Partner X100 DUT X101 Link Partner X200 DUT X210 DUT X211 Link Partner D C B A D C B A FWD REV FWD REV FWD REV FWD REV X111 X113 X115 X117 X119 X121 X123 X125 X112 X114 X1...

Страница 6: ...ng the Board The appropriate DUT and probe connection depends on the test case The R S ScopeSuite software provides a step by step guide that shows the required setup for each test case The test preparation and measurements of the test cases are described in the R S RTO R S RTP Ethernet Compliance Tests Test Procedures Manual ...

Отзывы: