Remote-control commands
R&S
®
SMW-K52/-K116
91
User Manual 1175.6778.02 ─ 19
Example:
See
Example "Configuring DVB-S2X signal in ACM mode"
Usage:
Query only
Manual operation:
See
5.9
TPS commands
[:SOURce<hw>]:BB:DVB:DVBH|DVBT:TPS:ID:PATTern
.......................................................91
[:SOURce<hw>]:BB:DVB:DVBH|DVBT:TPS:ID:STATe
..........................................................91
[:SOURce<hw>]:BB:DVB:DVBH|DVBT:TPS:MFEC[:STATe]
..................................................92
[:SOURce<hw>]:BB:DVB:DVBH|DVBT:TPS:TSLicing[:STATe]?
.............................................92
[:SOURce<hw>]:BB:DVB:DVBH|DVBT:TPS:ID:PATTern
<Pattern>, <BitCount>
Sets the pattern for cell identification.
Parameters:
<Pattern>
numeric
*RST:
#H0000
<BitCount>
integer
Range:
16 to 16
*RST:
16
Example:
:SOURce1:BB:DVB:STANdard DVBH
:SOURce1:BB:DVB:DVBH:HMODe?
// Response: NHI
:SOURce1:BB:DVB:DVBH|DVBT:TPS:TSLIcing:STATe?
// 1
:SOURce1:BB:DVB:DVBH|DVBT:TPS:ID:STATe?
// 1
:SOURce1:BB:DVB:DVBH:TPS:ID:PATTern #HAAAA,16
:SOURce1:BB:DVB:DVBH:TPS:MFEC:STATe 1
Manual operation:
See
[:SOURce<hw>]:BB:DVB:DVBH|DVBT:TPS:ID:STATe
<State>
Activates/deactivates the TPS cell identification.
Parameters:
<State>
1 | ON | 0 | OFF
Example:
See
[:SOURce<hw>]:BB:DVB:DVBH|DVBT:TPS:ID:
Manual operation:
See
TPS commands