Remote Control Commands
R&S
®
RTM3000
551
User Manual 1335.9090.02 ─ 08
SPECtrum:DIAGram:COLor:MINimum[:LEVel]
<MinimumLevel>
Sets the level used as a minimum of the color scale selected with
DIAGram:COLor:SCHeme:SPECtrogram
SPECtrum:DIAGram:COLor:SCHeme:
.
All level values lower than the minimum are displayed with the minimum color.
Parameters:
<MinimumLevel>
SPECtrum:DIAGram:COLor:SCHeme:FDOMain
<ColorScheme>
Sets the color scale for the display of the waveform in the frequency domain diagram.
Parameters:
<ColorScheme>
MONochrome | TEMPerature | RAINbow
SPECtrum:DIAGram:COLor:SCHeme:SPECtrogram
<ColorScheme>
Sets the color scale for the display of the spectrogram.
Parameters:
<ColorScheme>
MONochrome | TEMPerature | RAINbow
SPECtrum:DIAGram:SPECtrogram[:ENABle]
<Enable>
Enables the display of the spectrum diagram.
Parameters:
<Enable>
ON | OFF
16.8.5
XY-Waveforms
DISPlay:MODE
<Mode>
Sets the diagram mode.
Parameters:
<Mode>
YT | XY
YT
Default time diagram with a time axis in x-direction and the sig-
nal amplitudes displayed in y-direction.
Applications
www.allice.de
Allice Messtechnik GmbH