Trigger
R&S
®
RTB2000
83
User Manual 1333.1611.02 ─ 11
► [Trigger] > "Trigger Type" = "Pattern" > "Edit Pattern"
Figure 5-7: Pattern trigger with logic editor
Thresholds
At the bottom of the "Logic Editor", you see the current threshold settings of all chan-
nels. Here, you can directly activate the channels, and change the threshold values.
The thresholds of analog channels are also set in the "Channel
<n>" > "Threshold"
menu, see also
Chapter 4.3.4, "Threshold settings"
The thresholds of logic channels are set in the "Logic" menu, see
Logic settings
H | L | X, Set All
Defines the pattern by selecting the state "H" (high), "L" (low) or "X" (do not care) for
each active analog and digital channel.
The word length of the pattern depends on the number of available analog and digital
channels.
Analog channels: 2 bit for 2-channel instruments, 4 bit for 4-channel instruments.
Digital (16 bit): the logic channels D0, D1,...,D15 are only available with MSO option
R&S
RTB-B1.
Thus the pattern can have 2, 4, 18, or 20 bits.
Use "Set
All" to set all channels to the same state.
Pattern trigger