Command Reference
R&S
®
CMW-KN5xx
87
User Manual 1176.7690.02 ─ 05
<SlopeAbsolute>
Slope component for calculation of the upper absolute limit line
of the area
Range:
-1000 dB/MHz to 1000 dB/MHz
*RST:
depends on <no> and <Band>
Default unit: dB/MHz
<LevelRelative>
Upper relative limit of the area
Range:
-256 dB to 256 dB
*RST:
-52 dB (<no> = 3) / OFF (<no> ≠ 3)
Default unit: dB
Additional parameters: OFF | ON (disables | enables the relative
limit)
<RBW>
K030 | K100 | M1
Resolution bandwidth to be used for the area
K030
: 30 kHz
K100
: 100 kHz
M1
: 1MHz
*RST:
K100 (<no> = 1, 2) / M1 (<no> = 3 to 10)
Example:
See
Firmware/Software:
V3.0.20
Manual operation:
See
6.3.10 Signal Configuration Information
The following commands return the modulation scheme specified indirectly via the E-
UTRA test model.
FETCh:LTE:MEAS<i>:ENB:MEValuation:MODulation?
READ:LTE:MEAS<i>:ENB:MEValuation:MODulation?
Returns the modulation scheme according to the configured E-UTRA test model.
Return values:
<Reliability>
<Modulation>
QPSK | Q16 | Q64
QPSK, 16-QAM, 64-QAM
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V3.0.20
6.3.11 EVM Results (Traces)
The following commands return the EVM vs OFDM symbol results of the multi evalua-
tion measurement.
Multi Evaluation Measurement Commands
深圳德标仪器