NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
84
User Manual 1178.5689.02 ─ 06
Remote command:
CONFigure:NIOT:SIGN<i>:SMS:OUTGoing:LHANdling
Outgoing Message Handling
Selects whether the message text is defined via the GUI or read from a file.
"Use Internal"
Use the message text configured via the GUI (
or
).
"From File"
Read the text from the file selected via
Remote command:
CONFigure:NIOT:SIGN<i>:SMS:OUTGoing:MESHandling
Outgoing SMS
Defines the message contents for outgoing 7-bit ASCII messages. Up to 800 charac-
ters are allowed.
This text is used for "Outgoing Message Handling" = "Use Internal" plus "Data Coding /
Character Set" = "7bit".
Remote command:
CONFigure:NIOT:SIGN<i>:SMS:OUTGoing:INTernal
Outgoing SMS binary
Defines the message contents for outgoing 8-bit binary messages. The contents are
entered as hexadecimal numbers. Up to 1400 digits are allowed.
This text is used for "Outgoing Message Handling" = "Use Internal" plus "Data Coding /
Character Set" = "8bit".
Remote command:
CONFigure:NIOT:SIGN<i>:SMS:OUTGoing:BINary
Protocol Identifier
Specifies the TP protocol identifier (TP-PID) value to be sent. The meaning of the val-
ues is defined in 3GPP TS 23.040 chapter 9.2.3.9.
Remote command:
CONFigure:NIOT:SIGN<i>:SMS:OUTGoing:PIDentifier
Data Coding / Character Set
Selects between the 7-bit ASCII message (
Remote command:
CONFigure:NIOT:SIGN<i>:SMS:OUTGoing:DCODing
User Data Header
To add a header to the TP user data field, enable the checkbox and configure the
header via the hex value. The structure of the user data header is defined in 3GPP TS
23.040, chapter 9.2.3.24.
The hex value configures the following parts of the header:
●
Information element identifier (IEI, one octet)
Currently supported values: #H05, #H70 to #H7F
GUI Reference