NB-IoT NPRACH Measurement
R&S
®
CMW-KM300/-KS300
368
User Manual 1178.5689.02 ─ 06
CONFigure:NIOT:MEAS<i>:PRACh:SCOunt:PDYNamics
<StatisticCount>
Specifies the statistic count of the measurement. The statistic count is equal to the
number of measurement intervals per single shot.
Parameters:
<StatisticCount>
Number of measurement intervals
Range:
1 to 1000
*RST:
1
Example:
See
Specifying Measurement-Specific Settings
Firmware/Software:
V3.7.20
Manual operation:
See
4.5.3.6
Trigger Settings
The following commands define the trigger parameters.
TRIGger:NIOT:MEAS<i>:PRACh:CATalog:SOURce?
.........................................................368
TRIGger:NIOT:MEAS<i>:PRACh:SOURce
........................................................................368
TRIGger:NIOT:MEAS<i>:PRACh:SLOPe
..........................................................................369
TRIGger:NIOT:MEAS<i>:PRACh:THReshold
.................................................................... 369
TRIGger:NIOT:MEAS<i>:PRACh:TOUT
............................................................................369
TRIGger:NIOT:MEAS<i>:PRACh:MGAP
...........................................................................370
TRIGger:NIOT:MEAS<i>:PRACh:CATalog:SOURce?
Lists all trigger source values that can be set using
.
Return values:
<Sourcelist>
Comma-separated list of all supported values. Each value is rep-
resented as a string.
Usage:
Query only
Firmware/Software:
V3.7.20
Manual operation:
See
TRIGger:NIOT:MEAS<i>:PRACh:SOURce
<Source>
Selects the source of the trigger events. Some values are always available. They are
listed below. Depending on the installed options, additional values are available. You
can query a list of all supported values via
TRIGger:...:CATalog:SOURce?
.
Parameters:
<Source>
'IF Power':
Power trigger (received RF power)
*RST:
'IF Power'
Example:
See
Configuring the Trigger System