NB-IoT Multi-Evaluation Measurement
R&S
®
CMW-KM300/-KS300
267
User Manual 1178.5689.02 ─ 06
CONFigure:NIOT:MEAS<i>:RFSettings:UMARgin
<UserMargin>
Sets the margin that the measurement adds to the expected nominal power to deter-
mine the reference power. The reference power minus the external input attenuation
must be within the power range of the selected input connector. Refer to the data
sheet.
For the combined signal path scenario, use
.
Parameters:
<UserMargin>
Range:
0 dB to (55 dB + external attenuation - expected
nominal power)
*RST:
0 dB
Default unit: dB
Example:
See
Specifying General and Common Measurement Settings
Firmware/Software:
V3.5.10
Manual operation:
See
CONFigure:NIOT:MEAS<i>:RFSettings:MLOFfset
<MixLevOffset>
Varies the input level of the mixer in the analyzer path.
For the combined signal path scenario, use
.
Parameters:
<MixLevOffset>
Range:
-10 dB to 10 dB
*RST:
0 dB
Default unit: dB
Example:
See
Specifying General and Common Measurement Settings
Firmware/Software:
V3.5.10
Manual operation:
See
3.5.3
Multi-Evaluation Measurement Commands
The commands for the NB-IoT multi-evaluation measurement are divided into the
groups listed below. The general measurement settings also affect the measurement,
see
Chapter 3.5.2, "General Measurement Settings"
Measurement Control and States
......................................................................... 268
..................................................................................270
Measurement Control Parameters
........................................................................272
.................................................................................................279
Command Reference