Remote Control Commands
R&S
®
NRPxxA(N)
69
User Manual 1177.6017.02 ─ 05
Example:
*TST?
Query
1
Response: Failed
Usage:
Query only
*WAI
WAIt to continue
Prevents the execution of the subsequent commands until all preceding commands
have been executed and all signals have settled.
Usage:
Event
9.4
Preparing for the Measurement
Before starting a measurement, you need to do the following:
Selecting the Reference Source
............................................................................. 69
...............................................................................69
............................................................................. 70
9.4.1
Selecting the Reference Source
The
ROSCillator
subsystem contains commands for configuring the reference
source.
[SENSe<Sensor>:]ROSCillator:SOURce
<source>
Sets the source of the reference oscillator. Refers typically to a precision, stabilized
time base.
Parameters:
<source>
INTernal | EXTernal | HOST
INTernal
Internal precision oscillator
EXTernal | HOST
External signal supplied at the host interface connector.
*RST:
INTernal
Example:
ROSC:SOUR INT
9.4.2
Selecting a Measurement Path
The
RANGe
subsystem contains commands for selection of a measurement path.
Preparing for the Measurement