Remote Control Commands for Phase Noise Measurements
R&S
®
FSW-K40
134
User Manual 1173.9286.02 ─ 15
Example:
CALC:SNO3:X 2MHz
Positions the third custom spot noise marker to an offset fre-
quency of 2 MHz.
Manual operation:
See
"On User Defined Offsets / Offset Frequency"
CALCulate<n>:SNOise<m>:Y?
This command queries the vertical position of a custom spot noise marker.
Suffix:
<n>
.
<m>
1...5
Selects the spot noise marker
Return values:
<Level>
<numeric value>
Phase noise level at the marker position.
Default unit: dBc/Hz
Example:
CALC:SNO3:Y?
Queries the level of the third custom spot noise marker.
Usage:
Query only
Manual operation:
See
See
"On User Defined Offsets / Offset Frequency"
DISPlay[:WINDow<n>]:TRACe<t>:SELect
<Trace>
This command selects the trace for which spot noise results are calculated.
A trace can only be selected if it has been turned on ("Trace Mode"
≠
Blank).
Suffix:
<n>, <t>
.
irrelevant
Parameters:
<Trace>
Number of the trace you want to select.
Range:
1 to 6
*RST:
1
Example:
DISP:TRAC:SEL 2
Selects trace number 2.
Manual operation:
See
8.11.4 Reading Out the Spur List
.................................................................................................135
.................................................................................. 135
.................................................................................. 135
Configure Numerical Result Displays